Report: in output mode, with each command sent as soon as the prompt
arrives, a command right after "output" or "modulation" (e.g. "level -30"
after "output off", or "mode low input" after "output off" twice) got no
prompt and was dropped with "Command timeout" after 20 s; the next
command worked.
Cause: after a direct command the shell set operation_requested = true,
which is OP_LEVER. The sweep thread left sweep(), found no command yet,
and ui_process() handled that "lever event" and then set
operation_requested = OP_NONE. When the shell had parsed the next command
in between (shell_function set, OP_CONSOLE set), that clear wiped
OP_CONSOLE. A zero span output mode sweep only returns when
operation_requested is set, so the command never ran. Caught on hardware
with a breakpoint on the clear: operation_requested 0x05 with cmd_level /
cmd_mode waiting, every time.
- ui_process() clears only the bit it handled, locked, so OP_CONSOLE
survives lever and touch handling (a touch, e.g. a remote "touch" from
tinySA-App, hit the same clear).
- The sweep thread clears OP_CONSOLE together with taking shell_function,
which the shell sets together, so a request left by a direct or timed
out command does not keep aborting sweeps.
- A direct command asks for the sweep restart with OP_CONSOLE instead of
a fake lever event.
- SI4432_Listen() keeps OP_CONSOLE on entry, so a command ends listen
mode instead of being lost the same way.
Tested on a ZS405 (HW V0.4.5.1): both reported sequences 15 rounds each
without a hang (release firmware: 7 of 7 hung), every reply < 0.5 s.
In zero span output mode the sweep thread loop passes once per direct
command ("output off/on", "level") and not while idle. Remote touches
mixed with commands in output mode: 10 rounds without a hang. Input mode
touch menu and sweeping work. Listen mode and the jog lever not tested
on hardware. ULTRA +88 bytes, BASIC +84 bytes.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>