Garage thermal protection

The hottest available CPU package controls the incident. An informational average cannot identify a hot individual machine and does not describe ambient temperature.

Stage CPU package condition Behavior
Warning At least 80 C / 176 F for ten minutes Send one quiet warning
Urgent At least 90 C / 194 F for two minutes Escalate the existing notification
Immediate urgent At least 95 C / 203 F Skip the urgent dwell
Recovery Every package below 75 C / 167 F for fifteen minutes Clear the incident and rearm

Incident state and dwell timing survive template updates. Short sensor fluctuations do not rearm the policy. Missing or stale readings cannot clear an incident; prolonged missing telemetry becomes a separate problem. An observation gap resets dwell timing while preserving an active incident. Dashboard graph colors show instantaneous readings and do not represent the dwell-based alert policy.

The temperature values are operating thresholds for this installation, not manufacturer limits. Package/core temperatures and ambient temperatures are different measurements.

Optional workload guard

An independent host-level guard monitors configured package readings and protects one site-configured optional camera workload. Its durable hold prevents a recovery loop after a thermal stop. Site-specific host bindings and access credentials belong in local configuration outside tracked source.

At urgent heat, the guard records the hold and requests a graceful stop of the optional container. If heat persists, it can request a graceful stop of the configured optional guest. Sustained severe heat can request a normal host shutdown after fresh temperature readings and configured cluster-safety checks confirm that shutdown is safe. The guard does not force-stop, start, migrate, or reboot workloads. An uncertain safety check blocks host shutdown and reports the reason.

The hold prevents automatic recovery of the optional workload. Release it only after verified cooling and review of workload placement, capacity, storage, and the cooling system. Releasing the hold does not start the workload. A physical host that has shut down requires operator recovery.

Validate the Home Assistant configuration and affected dashboards before rollout. Exercise dwell, stale-telemetry, hold, and graceful-stop cases with controlled test fixtures. Do not heat equipment artificially to test the guard.

For operator tests, use checksum-verified snapshots of the installed host and camera guards. Import their functions with isolated state and fake command adapters; never invoke the installed programs as an operational test. Verify the installed checksums again after the run so a stale source copy cannot masquerade as current production coverage. The notification template and the independent host/guest shutdown guard protect separate boundaries and both need fixtures.