Fix longstanding bug where multiple TGs got assigned to dial

pull/4/head
Simon 2 years ago
parent 763c240488
commit f7804a2515

@ -298,19 +298,38 @@ def reset_static_tg(tg,ts,_tmout,system):
logger.exception('(%s) KeyError in reset_static_tg() - bridge gone away? TG: %s',system,tg)
return
def reset_default_reflector(reflector,_tmout,system):
bridge = ''.join(['#',str(reflector)])
#_tmout = CONFIG['SYSTEMS'][system]['DEFAULT_UA_TIMER']
if bridge not in BRIDGES:
BRIDGES[bridge] = []
make_single_reflector(bytes_3(reflector),_tmout, system)
bridgetemp = deque()
for bridgesystem in BRIDGES[bridge]:
if bridgesystem['SYSTEM'] == system and bridgesystem['TS'] == 2:
bridgetemp.append({'SYSTEM': system, 'TS': 2, 'TGID': bytes_3(9),'ACTIVE': False,'TIMEOUT': _tmout * 60,'TO_TYPE': 'ON','OFF': [],'ON': [bytes_3(reflector),],'RESET': [], 'TIMER': time() + (_tmout * 60)})
else:
bridgetemp.append(bridgesystem)
BRIDGES[bridge] = bridgetemp
# def reset_default_reflector(reflector,_tmout,system):
# print(reflector)
# bridge = ''.join(['#',str(reflector)])
# print(bridge)
# #_tmout = CONFIG['SYSTEMS'][system]['DEFAULT_UA_TIMER']
# if bridge not in BRIDGES:
# BRIDGES[bridge] = []
# make_single_reflector(bytes_3(reflector),_tmout, system)
# bridgetemp = deque()
# for bridgesystem in BRIDGES[bridge]:
# print(bridgesystem)
# if bridgesystem['SYSTEM'] == system and bridgesystem['TS'] == 2:
# print(bridgesystem)
# bridgetemp.append({'SYSTEM': system, 'TS': 2, 'TGID': bytes_3(9),'ACTIVE': False,'TIMEOUT': _tmout * 60,'TO_TYPE': 'ON','OFF': [],'ON': [bytes_3(reflector),],'RESET': [], 'TIMER': time() + (_tmout * 60)})
# else:
# bridgetemp.append(bridgesystem)
# print(bridgetemp)
# BRIDGES[bridge] = bridgetemp
# print(BRIDGES[bridge])
def reset_all_reflector_system(_tmout,system):
for system in CONFIG['SYSTEMS']:
for bridge in BRIDGES:
if bridge[0:1] == '#':
for bridgesystem in BRIDGES[bridge]:
bridgetemp = deque()
if bridgesystem['SYSTEM'] == system and bridgesystem['TS'] == 2:
bridgetemp.append({'SYSTEM': system, 'TS': 2, 'TGID': bytes_3(9),'ACTIVE': False,'TIMEOUT': _tmout * 60,'TO_TYPE': 'ON','OFF': [],'ON': [bytes_3(int(bridge[1:])),],'RESET': [], 'TIMER': time() + (_tmout * 60)})
else:
bridgetemp.append(bridgesystem)
BRIDGES[bridge] = bridgetemp
def make_single_reflector(_tgid,_tmout,_sourcesystem):
_tgid_s = str(int_id(_tgid))
@ -1034,14 +1053,14 @@ def options_config():
if int(_options['DEFAULT_REFLECTOR']) != CONFIG['SYSTEMS'][_system]['DEFAULT_REFLECTOR']:
if int(_options['DEFAULT_REFLECTOR']) > 0:
logger.debug('(OPTIONS) %s default reflector changed, updating',_system)
reset_default_reflector(CONFIG['SYSTEMS'][_system]['DEFAULT_REFLECTOR'],_tmout,_system)
reset_all_reflector_system(_tmout,_system)
make_default_reflector(int(_options['DEFAULT_REFLECTOR']),_tmout,_system)
elif int(_options['DEFAULT_REFLECTOR']) in prohibitedTGs and not bool(_options['DEFAULT_REFLECTOR']):
logger.debug('(OPTIONS) %s default reflector is prohibited, ignoring change',_system)
else:
logger.debug('(OPTIONS) %s default reflector disabled, updating',_system)
reset_default_reflector(int(_options['DEFAULT_REFLECTOR']),_tmout,_system)
reset_all_reflector_system(_tmout,_system)
ts1 = []
if _options['TS1_STATIC'] != CONFIG['SYSTEMS'][_system]['TS1_STATIC']:

Loading…