# @CCOSTAN - Follow Me on X
# For more info visit https://www.vcloudinfo.com/click-here
# Original Repo : https://github.com/CCOSTAN/Home-AssistantConfig
# -------------------------------------------------------------------
# Tesla Powerwall - Monitoring and outage automations
# Related Issue: 1490
# Related Issue: 1550
# Related Issue: 1571
# Related Issue: 1598
# Related Issue: 1936
# Powerwall status sensors, outage alerting, and load-shedding helpers.
# -------------------------------------------------------------------
# Video: https://youtu.be/hR_0lFEE2bA
# Blog: https://www.vcloudinfo.com/2026/06/tesla-powerwall-home-assistant-watchdog.html
# Notes: Read more https://www.vcloudinfo.com/2018/01/going-green-to-save-some-green-in-2018.html | Existing Issue #272
# Tesla Powerwall added via UI Integration
# Notes: Home Assistant owns staged resilience policy; recommendations remain monitor-only until coordinated actions are approved.
# Notes: The outage anchor uses one restoring input_datetime so stage timing survives Home Assistant restarts.
######################################################################
# Binary Sensors:
# - binary_sensor.powerwall_charging ............. battery_charging (on=charging)
# - binary_sensor.powerwall_connected_to_tesla ... connectivity (on=connected)
# - binary_sensor.powerwall_grid_services_active .. power (on=active)
# - binary_sensor.powerwall_grid_status .......... power (on=grid up)
# - binary_sensor.powerwall_status ............... power (on=system ok)
#
# Power & Energy Sensors:
# - sensor.powerwall_charge ...................... battery %, 0–100
# - sensor.powerwall_backup_reserve .............. reserve %, 0–100
# - sensor.powerwall_battery_power ............... kW (+discharge / -charge)
# - sensor.powerwall_load_power .................. kW house load
# - sensor.powerwall_site_power .................. kW (+export / -import)
# - sensor.powerwall_solar_power ................. kW solar production
#
# Lifetime kWh Meters:
# - sensor.powerwall_battery_export .............. kWh -> grid/load
# - sensor.powerwall_battery_import .............. kWh <- battery charged
# - sensor.powerwall_load_export ................. kWh exported from loads
# - sensor.powerwall_load_import ................. kWh imported to loads
# - sensor.powerwall_site_export ................. kWh site -> grid
# - sensor.powerwall_site_import ................. kWh site <- grid
# - sensor.powerwall_solar_export ................ kWh solar -> site/battery/grid
# - sensor.powerwall_solar_import ................ kWh solar <- grid (rare)
#
# Switches:
# - switch.powerwall_off_grid_operation .......... island mode toggle
######################################################################
input_datetime:
power_resilience_outage_started:
name: Power Resilience Outage Started
icon: mdi:transmission-tower-off
has_date: true
has_time: true
template:
- sensor:
- name: "Power Resilience Recommended Stage"
unique_id: power_resilience_recommended_stage
icon: mdi:home-assistant
state: >-
{% set grid = states('binary_sensor.powerwall_grid_status') %}
{% set charge_raw = states('sensor.powerwall_charge') %}
{% set anchor_raw = states('input_datetime.power_resilience_outage_started') %}
{% set anchor_valid = anchor_raw not in ['unknown', 'unavailable', 'none', ''] and anchor_raw != '2000-01-01 00:00:00' %}
{% set outage_seconds = (as_timestamp(now()) - as_timestamp(anchor_raw, as_timestamp(now()))) if anchor_valid else 0 %}
{% if grid not in ['on', 'off'] or not is_number(charge_raw) %}
TELEMETRY_UNAVAILABLE
{% elif grid == 'on' %}
NORMAL
{% elif not anchor_valid %}
TELEMETRY_UNAVAILABLE
{% elif outage_seconds < 600 %}
OBSERVE
{% elif charge_raw | float(0) <= 25 %}
PRESERVE
{% elif charge_raw | float(0) <= 50 %}
SHED_2
{% elif charge_raw | float(0) <= 75 %}
SHED_1
{% else %}
OBSERVE
{% endif %}
attributes:
control_owner: Home Assistant
execution_mode: monitor_only
actions_armed: "{{ false }}"
grid_status: "{{ states('binary_sensor.powerwall_grid_status') }}"
powerwall_charge: >-
{% set charge = states('sensor.powerwall_charge') %}
{{ charge | float if is_number(charge) else none }}
outage_started_at: >-
{% set anchor = states('input_datetime.power_resilience_outage_started') %}
{{ anchor if is_state('binary_sensor.powerwall_grid_status', 'off') and anchor not in ['unknown', 'unavailable', 'none', '', '2000-01-01 00:00:00'] else none }}
outage_elapsed_seconds: >-
{% set anchor = states('input_datetime.power_resilience_outage_started') %}
{% if is_state('binary_sensor.powerwall_grid_status', 'off') and anchor not in ['unknown', 'unavailable', 'none', '', '2000-01-01 00:00:00'] %}
{{ [0, as_timestamp(now()) - as_timestamp(anchor, as_timestamp(now()))] | max | round(0) | int }}
{% else %}
0
{% endif %}
observation_seconds: "{{ 600 }}"
shed_1_threshold: "{{ 75 }}"
shed_2_threshold: "{{ 50 }}"
preserve_threshold: "{{ 25 }}"
garage_ups_status: "{{ states('sensor.garage_ups_status') }}"
office_ups_status: "{{ states('sensor.office_ups_eaton_550_status') }}"
office_cyberpower_ups_status: "{{ states('sensor.office_ups_cyberpower_status') }}"
#-------------------------------------------
script:
powerwall_turn_off_nonessential_lights:
alias: "Powerwall - Turn Off Non-Essential Lights"
sequence:
- service: homeassistant.turn_off
target:
entity_id:
- group.interior_lights
- group.exterior_lights
- switch.kitchen_accent_2
- switch.master_bathroom_accent_2
powerwall_outage_live_activity_update:
alias: "Powerwall - Outage Live Activity Update"
description: Refresh the tagged outage live activity using native grid-status state metadata.
mode: queued
sequence:
- variables:
grid_entity: "{{ states.binary_sensor.powerwall_grid_status if states.binary_sensor.powerwall_grid_status is defined else none }}"
outage_started_ts: >-
{% if grid_entity is not none and grid_entity.state == 'off' %}
{{ as_timestamp(grid_entity.last_changed, 0) | int(0) }}
{% else %}
0
{% endif %}
charge_pct: >-
{% set charge = states('sensor.powerwall_charge') %}
{% if charge not in ['unknown', 'unavailable', 'none', ''] %}
{{ charge | float(0) | round(0) | int(0) }}
{% else %}
0
{% endif %}
outage_started_label: >-
{% if outage_started_ts > 0 %}
{{ as_datetime(outage_started_ts) | as_local | strftime('%I:%M %p') }}
{% else %}
unknown
{% endif %}
- condition: template
value_template: "{{ outage_started_ts > 0 }}"
- service: script.notify_live_activity
data:
who: parents
tag: powerwall_grid_outage
title: "Power outage"
message: "Grid outage since {{ outage_started_label }}. Powerwall charge at {{ charge_pct }}%."
icon: mdi:transmission-tower-off
color: "#E65100"
progress: "{{ charge_pct }}"
progress_max: 100
chronometer: true
when: "{{ outage_started_ts }}"
when_relative: false
automation:
- alias: "Power Resilience - Track Outage Anchor"
id: 0d2400c4-6e2e-4f17-9ca5-b899ad80f056
description: Persist the active grid outage start for restart-safe, Home Assistant-owned stage recommendations.
mode: queued
max: 3
triggers:
- trigger: homeassistant
event: start
id: startup
- trigger: state
entity_id: binary_sensor.powerwall_grid_status
to: "off"
id: grid_off
- trigger: state
entity_id: binary_sensor.powerwall_grid_status
to: "on"
id: grid_on
actions:
- choose:
- conditions:
- condition: state
entity_id: binary_sensor.powerwall_grid_status
state: "off"
- condition: or
conditions:
- condition: template
value_template: >-
{{ trigger.id == 'grid_off' and trigger.from_state is not none and
trigger.from_state.state == 'on' }}
- condition: template
value_template: >-
{{ states('input_datetime.power_resilience_outage_started') in
['unknown', 'unavailable', 'none', '', '2000-01-01 00:00:00'] }}
sequence:
- action: input_datetime.set_datetime
target:
entity_id: input_datetime.power_resilience_outage_started
data:
datetime: "{{ now().strftime('%Y-%m-%d %H:%M:%S') }}"
- conditions:
- condition: trigger
id:
- startup
- grid_on
- condition: state
entity_id: binary_sensor.powerwall_grid_status
state: "on"
sequence:
- action: input_datetime.set_datetime
target:
entity_id: input_datetime.power_resilience_outage_started
data:
datetime: "2000-01-01 00:00:00"
- alias: "Powerwall outage - Refresh live activity"
id: 5b5fb370-c6cb-4c74-95d4-264737e4456f
description: Start the tagged outage live activity when the grid drops and refresh it when charge changes.
mode: restart
trigger:
- id: grid_off
platform: state
entity_id: binary_sensor.powerwall_grid_status
to: 'off'
- id: charge_change
platform: state
entity_id: sensor.powerwall_charge
action:
- choose:
- conditions:
- condition: trigger
id: grid_off
- condition: template
value_template: >-
{{ trigger.to_state is not none and trigger.from_state is not none and
trigger.to_state.state not in ['unknown', 'unavailable', 'null'] and
trigger.from_state.state not in ['unknown', 'unavailable', 'null'] }}
sequence:
- service: script.powerwall_outage_live_activity_update
- conditions:
- condition: trigger
id: charge_change
- condition: state
entity_id: binary_sensor.powerwall_grid_status
state: 'off'
- condition: template
value_template: "{{ trigger.to_state is not none and trigger.to_state.state not in ['unknown', 'unavailable', 'none', ''] }}"
sequence:
- service: script.powerwall_outage_live_activity_update
- alias: "Powerwall outage - Clear live activity"
id: 1d998f72-50df-46eb-b335-7f0d9974f89a
description: Clear the tagged outage live activity after the grid is stable again.
mode: single
trigger:
- platform: state
entity_id: binary_sensor.powerwall_grid_status
from: 'off'
to: 'on'
for:
minutes: 2
action:
- service: script.notify_live_activity
data:
who: parents
tag: powerwall_grid_outage
clear: true
- alias: Notify if Grid is down
id: 56a32121-5725-4510-a1fa-10f69a5c82ef
trigger:
- platform: state
entity_id: binary_sensor.powerwall_grid_status
condition:
- condition: template
# Check that both current and previous states are not 'unavailable', 'unknown', or 'null'.
value_template: >-
{{ states('binary_sensor.powerwall_grid_status') not in ['unavailable', 'unknown', 'null'] and
trigger.from_state.state not in ['unavailable', 'unknown', 'null'] }}
action:
- service: script.send_to_logbook
data:
topic: "POWER"
message: >-
Grid status is {{ (trigger.to_state.state)|replace('on', 'up')|replace('off', 'down') }}.
- service: script.notify_engine
data:
title: "Electrical Grid Status {{ (trigger.to_state.state)|replace('on', 'up')|replace('off', 'down') }}."
value1: "Please verify with the Tesla App."
who: 'parents'
group: 'information'
# https://github.com/CCOSTAN/Home-AssistantConfig/issues/779
- alias: Shut Things down if running on PowerWall
mode: restart
id: 37288a96-5f49-46c2-85c8-7e8794d23612
trigger:
- platform: state
entity_id: binary_sensor.powerwall_grid_status
to: 'off'
action:
- repeat:
count: 3
sequence:
- choose:
- conditions:
- condition: template
value_template: "{{ repeat.index == 2 }}"
sequence:
- delay:
minutes: 1
- conditions:
- condition: template
value_template: "{{ repeat.index == 3 }}"
sequence:
- delay:
minutes: 3
- service: script.powerwall_turn_off_nonessential_lights
- choose:
- conditions:
- condition: template
value_template: "{{ repeat.index == 1 }}"
sequence:
- service: script.notify_engine
data:
title: "Electrical Grid Status {{ (trigger.to_state.state)|replace('True', 'up')|replace('False', 'down') }}."
value1: "Taking actions to turning off the House Lights to preserve Battery Power."
who: 'family'
group: 'information'
- conditions:
- condition: template
value_template: "{{ repeat.index == 2 }}"
sequence:
- service: script.speech_engine
data:
value1: "Because of the Power Outage, the Lights will be recycled for 3 minutes. Lights may turn on and off during this time."
- conditions:
- condition: template
value_template: "{{ repeat.index == 3 }}"
sequence:
- service: script.speech_engine
data:
value1: "Automatic light recycling has been completed. Any abnormalities will have to be addressed in the Hue App most likely. "
- alias: "Powerwall Low Charge Monitoring and Recovery"
id: fda6116b-b2a5-4198-a1ce-4cf4bb3254b2
mode: single
trigger:
- id: low_24h
platform: numeric_state
entity_id: sensor.powerwall_charge
below: 60
for:
hours: 24
- id: recovered
platform: numeric_state
entity_id: sensor.powerwall_charge
above: 60
for:
minutes: 10
condition:
- condition: state
entity_id: binary_sensor.powerwall_grid_status
state: 'on'
action:
- choose:
- conditions:
- condition: trigger
id: low_24h
sequence:
- service: script.send_to_logbook
data:
topic: "POWER"
message: "Powerwall charge below 60% for 24h (current: {{ states('sensor.powerwall_charge') }}%)."
- service: repairs.create
data:
issue_id: "powerwall_low_charge_60_24h"
title: "Powerwall charge low for 24h"
severity: "warning"
persistent: true
description: >-
Powerwall has been below 60% for 24 hours while the grid is online.
Current charge: {{ states('sensor.powerwall_charge') }}%.
- service: script.notify_engine
data:
title: "Powerwall Low Charge Alert - Current Charge: {{ states('sensor.powerwall_charge') }}"
value1: "The Powerwall has been below 50% charge for more than 24 hours while the grid is online. This may indicate an issue."
who: 'parents'
group: 'information'
- conditions:
- condition: trigger
id: recovered
sequence:
- service: repairs.remove
continue_on_error: true
data:
issue_id: "powerwall_low_charge_60_24h"
- service: script.send_to_logbook
data:
topic: "POWER"
message: "Powerwall charge recovered above 60%. Cleared repair issue."
- alias: "Powerwall outage - Rheem WH mode control"
id: d686f650-65ad-4cc6-8e27-8b5ee76b5338
description: "During outages, switch Rheem between off and electric mode while the compressor is under warranty repair"
mode: single
trigger:
- id: sunrise
platform: sun
event: sunrise
- id: charge_above_50
platform: numeric_state
entity_id: sensor.powerwall_charge
above: 50
for:
minutes: 5
- id: sunset
platform: sun
event: sunset
- id: grid_off_1m
platform: state
entity_id: binary_sensor.powerwall_grid_status
to: 'off'
for:
minutes: 1
condition:
- condition: state
entity_id: binary_sensor.powerwall_grid_status
state: 'off'
action:
- choose:
- conditions:
- condition: template
value_template: "{{ trigger.id in ['sunset', 'grid_off_1m'] }}"
- condition: or
conditions:
- condition: sun
after: sunset
- condition: sun
before: sunrise
sequence:
- service: water_heater.set_operation_mode
target:
entity_id: water_heater.rheem_wh
data:
state: off
- conditions:
- condition: template
value_template: "{{ trigger.id in ['sunrise', 'charge_above_50', 'grid_off_1m'] }}"
- condition: numeric_state
entity_id: sensor.powerwall_charge
above: 50
- condition: sun
after: sunrise
before: sunset
sequence:
- service: water_heater.set_operation_mode
target:
entity_id: water_heater.rheem_wh
data:
state: electric
# https://github.com/CCOSTAN/Home-AssistantConfig/issues/547
- alias: Turn off the Nest Thermostats during a Power Outage
id: 022bd9da-ab7c-4c1b-9e95-2ff4ffe5f9cc
trigger:
- platform: state
entity_id: binary_sensor.powerwall_grid_status
to: 'off'
for:
minutes: 6
condition:
- condition: template
value_template: "{{ states('binary_sensor.powerwall_grid_status') == 'off' }}"
action:
- service: script.reconcile_hvac_state
data:
reason: "grid outage"
- service: script.notify_engine
data:
title: "Electrical Grid Status {{ (trigger.to_state.state)|replace('True', 'up')|replace('False', 'down') }}."
value1: "Taking actions to turning off the AC units to preserve Battery Power."
who: 'family'
group: 'information'
- alias: Turn back on the Nest Thermostats after a Power Outage
id: 14faf84b-cb24-4391-a97f-b83479a67fc7
trigger:
- platform: state
entity_id: binary_sensor.powerwall_grid_status
from: 'off'
to: 'on'
for:
minutes: 10
action:
- service: script.reconcile_hvac_state
data:
reason: "grid restored"
- service: script.notify_engine
data:
title: "Electrical Grid Status {{ (trigger.to_state.state)|replace('True', 'up')|replace('False', 'down') }}."
value1: "HVAC settings were reconciled with grid, entry-point, and occupancy conditions."
who: 'family'
group: 'information'

Powered by TurnKey Linux.