Distinguish water heater faults from stale telemetry

master
Carlo Costanzo 5 days ago
parent 0483192e73
commit c18b0bc08b

@ -14,7 +14,7 @@
# Powerwall outage control for Rheem WH lives in config/packages/powerwall.yaml
# Notes: EcoNet exposes an alert count but not the vendor error code or message.
# Notes: New alert-count increases notify once; state changes and 15-minute reconciliation keep Repairs durable.
# Notes: A 10-minute EcoNet data gap is telemetry stale, not proof of a water-heater fault.
# Notes: A 10-minute data gap raises a connectivity warning. A reported heater fault takes priority.
######################################################################
##############################################################################
@ -239,30 +239,48 @@ automation:
value_template: "{{ states('binary_sensor.rheem_wh_problem') in ['on', 'off'] }}"
action:
- variables:
alert_count: "{{ states('sensor.rheem_wh_alert_count') | int(0) }}"
diagnostic_status: "{{ states('sensor.rheem_wh_diagnostic_status') }}"
reasons: "{{ state_attr('binary_sensor.rheem_wh_problem', 'reasons') or [] }}"
telemetry_only: "{{ reasons == ['telemetry_stale'] }}"
incident_title: >-
{% if is_state('binary_sensor.rheem_wh_active_alert', 'on') %}
{% if 'active_alert' in reasons %}
Rheem water heater alert
{% elif is_state('binary_sensor.rheem_wh_telemetry_stale', 'on') %}
{% elif telemetry_only %}
Rheem telemetry unavailable
{% else %}
Rheem water heater health degraded
{% endif %}
incident_description: |-
Home Assistant detected a Rheem water-heater problem.
{% if telemetry_only %}
Home Assistant has been missing EcoNet readings for at least 10 minutes. Check the heater's control panel for its current status.
{% if config_entry_attr(config_entry_id('water_heater.rheem_wh'), 'state') in ['setup_retry', 'setup_in_progress'] %}
Home Assistant is retrying the EcoNet connection automatically.
{% endif %}
{% else %}
{% if 'active_alert' in reasons %}
EcoNet reports an active heater alert. Check the Rheem app or vendor email for the diagnostic code and message.
{% else %}
EcoNet reports heater health below the 90% threshold.
{% endif %}
{% if 'telemetry_stale' in reasons %}
Status: {{ states('sensor.rheem_wh_diagnostic_status') }}
Active alert count: {{ states('sensor.rheem_wh_alert_count') }}
Operation mode: {{ states('water_heater.rheem_wh') }}
Running state: {{ states('sensor.rheem_wh_running_state') }}
Available hot water: {{ states('sensor.rheem_wh_available_hot_water') }}%
Compressor health: {{ states('sensor.rheem_wh_compressor_health') }}%
Tank health: {{ states('sensor.rheem_wh_tank_health') }}%
Last new-alert snapshot: {{ states('sensor.rheem_wh_last_alert_snapshot') }}
Some EcoNet readings are also unavailable.
{% endif %}
EcoNet exposes the number of alerts but not the vendor error code or message.
Check the Rheem app or vendor email for the exact diagnostic wording.
{% for label, entity in [
('Active alerts', 'sensor.rheem_wh_alert_count'),
('Operation mode', 'water_heater.rheem_wh'),
('Running state', 'sensor.rheem_wh_running_state'),
('Available hot water', 'sensor.rheem_wh_available_hot_water'),
('Compressor health', 'sensor.rheem_wh_compressor_health'),
('Tank health', 'sensor.rheem_wh_tank_health')] if has_value(entity) -%}
- {{ label }}: {{ states(entity, with_unit=true) }}
{% endfor %}
{% if 'active_alert' in reasons and has_value('sensor.rheem_wh_last_alert_snapshot') %}
Last recorded alert-count increase: {{ states('sensor.rheem_wh_last_alert_snapshot') }}
{% endif %}
{% endif %}
- choose:
- conditions:
- condition: template
@ -316,11 +334,7 @@ automation:
issue_id: "rheem_water_heater_problem"
domain: "econet"
title: "{{ incident_title }}"
severity: >-
{{ 'warning'
if is_state('binary_sensor.rheem_wh_telemetry_stale', 'on')
and not is_state('binary_sensor.rheem_wh_active_alert', 'on')
else 'error' }}
severity: "{{ 'warning' if telemetry_only else 'error' }}"
persistent: true
description: "{{ incident_description }}"
- service: persistent_notification.create

Loading…
Cancel
Save

Powered by TurnKey Linux.