@ -14,7 +14,7 @@
|
|
|
|
|
# Powerwall outage control for Rheem WH lives in config/packages/powerwall.yaml
|
|
|
|
|
# Notes: EcoNet exposes an alert count but not the vendor error code or message.
|
|
|
|
|
# Notes: New alert-count increases notify once; state changes and 15-minute reconciliation keep Repairs durable.
|
|
|
|
|
# Notes: A 10-minute EcoNet data gap is telemetry stale, not proof of a water-heater fault.
|
|
|
|
|
# Notes: A 10-minute data gap raises a connectivity warning. A reported heater fault takes priority.
|
|
|
|
|
######################################################################
|
|
|
|
|
|
|
|
|
|
##############################################################################
|
|
|
|
|
@ -239,30 +239,48 @@ automation:
|
|
|
|
|
value_template: "{{ states('binary_sensor.rheem_wh_problem') in ['on', 'off'] }}"
|
|
|
|
|
action:
|
|
|
|
|
- variables:
|
|
|
|
|
alert_count: "{{ states('sensor.rheem_wh_alert_count') | int(0) }}"
|
|
|
|
|
diagnostic_status: "{{ states('sensor.rheem_wh_diagnostic_status') }}"
|
|
|
|
|
reasons: "{{ state_attr('binary_sensor.rheem_wh_problem', 'reasons') or [] }}"
|
|
|
|
|
telemetry_only: "{{ reasons == ['telemetry_stale'] }}"
|
|
|
|
|
incident_title: >-
|
|
|
|
|
{% if is_state('binary_sensor.rheem_wh_active_alert', 'on') %}
|
|
|
|
|
{% if 'active_alert' in reasons %}
|
|
|
|
|
Rheem water heater alert
|
|
|
|
|
{% elif is_state('binary_sensor.rheem_wh_telemetry_stale', 'on') %}
|
|
|
|
|
{% elif telemetry_only %}
|
|
|
|
|
Rheem telemetry unavailable
|
|
|
|
|
{% else %}
|
|
|
|
|
Rheem water heater health degraded
|
|
|
|
|
{% endif %}
|
|
|
|
|
incident_description: |-
|
|
|
|
|
Home Assistant detected a Rheem water-heater problem.
|
|
|
|
|
{% if telemetry_only %}
|
|
|
|
|
Home Assistant has been missing EcoNet readings for at least 10 minutes. Check the heater's control panel for its current status.
|
|
|
|
|
{% if config_entry_attr(config_entry_id('water_heater.rheem_wh'), 'state') in ['setup_retry', 'setup_in_progress'] %}
|
|
|
|
|
|
|
|
|
|
Home Assistant is retrying the EcoNet connection automatically.
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% else %}
|
|
|
|
|
{% if 'active_alert' in reasons %}
|
|
|
|
|
EcoNet reports an active heater alert. Check the Rheem app or vendor email for the diagnostic code and message.
|
|
|
|
|
{% else %}
|
|
|
|
|
EcoNet reports heater health below the 90% threshold.
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% if 'telemetry_stale' in reasons %}
|
|
|
|
|
|
|
|
|
|
Status: {{ states('sensor.rheem_wh_diagnostic_status') }}
|
|
|
|
|
Active alert count: {{ states('sensor.rheem_wh_alert_count') }}
|
|
|
|
|
Operation mode: {{ states('water_heater.rheem_wh') }}
|
|
|
|
|
Running state: {{ states('sensor.rheem_wh_running_state') }}
|
|
|
|
|
Available hot water: {{ states('sensor.rheem_wh_available_hot_water') }}%
|
|
|
|
|
Compressor health: {{ states('sensor.rheem_wh_compressor_health') }}%
|
|
|
|
|
Tank health: {{ states('sensor.rheem_wh_tank_health') }}%
|
|
|
|
|
Last new-alert snapshot: {{ states('sensor.rheem_wh_last_alert_snapshot') }}
|
|
|
|
|
Some EcoNet readings are also unavailable.
|
|
|
|
|
{% endif %}
|
|
|
|
|
|
|
|
|
|
EcoNet exposes the number of alerts but not the vendor error code or message.
|
|
|
|
|
Check the Rheem app or vendor email for the exact diagnostic wording.
|
|
|
|
|
{% for label, entity in [
|
|
|
|
|
('Active alerts', 'sensor.rheem_wh_alert_count'),
|
|
|
|
|
('Operation mode', 'water_heater.rheem_wh'),
|
|
|
|
|
('Running state', 'sensor.rheem_wh_running_state'),
|
|
|
|
|
('Available hot water', 'sensor.rheem_wh_available_hot_water'),
|
|
|
|
|
('Compressor health', 'sensor.rheem_wh_compressor_health'),
|
|
|
|
|
('Tank health', 'sensor.rheem_wh_tank_health')] if has_value(entity) -%}
|
|
|
|
|
- {{ label }}: {{ states(entity, with_unit=true) }}
|
|
|
|
|
{% endfor %}
|
|
|
|
|
{% if 'active_alert' in reasons and has_value('sensor.rheem_wh_last_alert_snapshot') %}
|
|
|
|
|
Last recorded alert-count increase: {{ states('sensor.rheem_wh_last_alert_snapshot') }}
|
|
|
|
|
{% endif %}
|
|
|
|
|
{% endif %}
|
|
|
|
|
- choose:
|
|
|
|
|
- conditions:
|
|
|
|
|
- condition: template
|
|
|
|
|
@ -316,11 +334,7 @@ automation:
|
|
|
|
|
issue_id: "rheem_water_heater_problem"
|
|
|
|
|
domain: "econet"
|
|
|
|
|
title: "{{ incident_title }}"
|
|
|
|
|
severity: >-
|
|
|
|
|
{{ 'warning'
|
|
|
|
|
if is_state('binary_sensor.rheem_wh_telemetry_stale', 'on')
|
|
|
|
|
and not is_state('binary_sensor.rheem_wh_active_alert', 'on')
|
|
|
|
|
else 'error' }}
|
|
|
|
|
severity: "{{ 'warning' if telemetry_only else 'error' }}"
|
|
|
|
|
persistent: true
|
|
|
|
|
description: "{{ incident_description }}"
|
|
|
|
|
- service: persistent_notification.create
|
|
|
|
|
|