diff --git a/docs/hdstack.md b/docs/hdstack.md index 0530d8a..c46d867 100644 --- a/docs/hdstack.md +++ b/docs/hdstack.md @@ -350,11 +350,14 @@ all-interface binding for ordinary deployments. The MUX's `--inventory-backend NUMBER,HOST,PORT` accepts only enabled FBP configuration entries and only public inventory fields. It excludes passphrases, -HBP peers, bridge state and all call events. Inventory entries carry +HBP peers, bridge state and raw aggregator call events from the combined feed. Inventory entries carry `REPORT_INVENTORY_ONLY=True`: consumers must not infer that an absence of call events means the link is idle. Generated HDStack FBP links carry the display-only `REPORT_INTERNAL=True` flag; external links default to false. These fields do -not affect packet forwarding. Existing consumers may ignore the added fields. +not affect packet forwarding. External links marked `REPORT_FBP_ACTIVITY=True` +also offer opt-in [live RX/TX observations](reporting-relay.md#live-external-freebridge-activity). +The separate DATA-GATEWAY and generated internal links are not external links. +Existing consumers may ignore the added fields. The MUX preserves the existing netstring reporting protocol and the main configuration's `REPORT_CLIENTS` allow-list. It merges worker configuration diff --git a/docs/release-notes-unreleased.md b/docs/release-notes-unreleased.md index bf20010..e941d3c 100644 --- a/docs/release-notes-unreleased.md +++ b/docs/release-notes-unreleased.md @@ -22,6 +22,8 @@ - Add loopback-only aggregator reporting to the existing MUX as an inventory-only source, allowing the dashboard to display external FBP links. Aggregator call - events and bridge snapshots are excluded, preserving worker/SQL event counts. + events and bridge snapshots are excluded from the ordinary feed, preserving + worker/SQL event counts. Console can separately subscribe to live, per-link + group-voice RX/TX on external FBPs, directly or via the optional SQL relay. - Mark generated internal HDStack links for optional dashboard filtering. - No routing, RF, FBP wire-format, public-port or data-admission changes. diff --git a/docs/reporting-relay.md b/docs/reporting-relay.md index e3f5de3..a8523a7 100644 --- a/docs/reporting-relay.md +++ b/docs/reporting-relay.md @@ -18,9 +18,10 @@ different container, and restrict access to that interface at the network boundary. Report configuration and bridge-state messages contain trusted Python pickle data and must not be exposed to untrusted clients. -The relay forwards upstream messages unchanged and caches only the latest -configuration and bridge-state messages so a newly connected dashboard can be -initialized immediately. SQL storage accepts both legacy events and extended +The relay forwards ordinary upstream messages unchanged and caches the latest +configuration and bridge state so a newly connected dashboard can be initialized +immediately. Optional FreeBridge activity is handled separately below. +SQL storage accepts both legacy events and extended events with trailing origin fields: ```text @@ -160,3 +161,34 @@ snapshots do not trigger Twisted's smaller default netstring limit. A lost backend connection is reported with its backend number and is re-established independently. See [hdstack.md](hdstack.md) for the generated container topology and configuration. + +### Live external FreeBridge activity + +The HDStack reporting MUX observes the aggregator's group-voice START/END +reports for each enabled, external FBP link. RX and TX are relative to the +local server. A single over may legitimately be RX on one link and TX on +several others; none of these observations is an additional Last Heard event. +There are no RF slot, payload, Talker Alias, credentials or keepalive fields. + +On the existing trusted report socket, a client can subscribe after CONFIG +advertises `REPORT_FBP_ACTIVITY=True` on an inventory entry. Send opcode +`0x08` followed by ASCII `1` (subscribe) or `0` (unsubscribe). The MUX sends +opcode `0x09` followed by a UTF-8 JSON snapshot immediately on subscription +and when observations change (updates within 100 ms may be combined): + +```json +{"3:SWC":[["RX",2342690,2350]],"3:Scotland":[["TX",2342690,2350]],"3:Other":[]} +``` + +Each row is direction, subscriber ID and TG. An empty list means no currently +observed group call, **not** proof of connectivity or remote reception. A call +already in progress when the MUX first attaches can be missed. A missing key +or `null` means activity is unavailable. Disconnect removes that source's +state. Calls without a reported end expire after 180 seconds; more than 64 +concurrent streams on a link marks it unknown until quiet for 180 seconds. +Snapshots exceeding 64 KiB are reported as `{}`, not sent as oversized frames. + +The optional SQL relay subscribes upstream only while a downstream client +wants activity, invalidates its activity cache on disconnect, and never sends +these frames to MySQL or to an unsubscribed client. No new listener, +configuration setting, schema change or change to RF or mesh forwarding is needed. diff --git a/report_mux.py b/report_mux.py index 8469d07..4cbe033 100644 --- a/report_mux.py +++ b/report_mux.py @@ -20,6 +20,7 @@ import argparse import copy +import json import pickle import signal @@ -31,6 +32,80 @@ from reporting_const import REPORT_OPCODES REPORT_FRAME_MAX_LENGTH = 10 * 1024 * 1024 +FBP_STREAM_LIFETIME = 180 +FBP_STREAMS_PER_LINK = 64 +FBP_ACTIVITY_MAX_BYTES = 64 * 1024 # Below the existing SQL relay's netstring limit. + + +class FBPActivity: + """Display observations only. FreeDMR identifies a stream within each link.""" + + def __init__(self, clock, changed): + self.clock = clock + self.changed = changed + self.links = {} + + def set_inventory(self, old, new): + before, after = ({k for k, v in cfg.items() if v.get('REPORT_FBP_ACTIVITY')} + for cfg in (old, new)) + for name in before - after: + for _, timer in self.links.pop(name).values(): + timer.cancel() + for name in after - before: + self.links[name] = {} + if before != after: + self.changed() + + def _expire(self, name, stream): + del self.links[name][stream] + self.changed() + + def observe(self, backend, payload): + fields = payload.split(b',', 9) + if (len(fields) < 9 or fields[0] != b'GROUP VOICE' + or fields[1] not in (b'START', b'END') or fields[2] not in (b'RX', b'TX') + or (fields[1] == b'END' and len(fields) < 10)): + return + name = prefixed_system_name(backend, fields[3].decode('utf-8')) + streams = self.links.get(name) + if streams is None: + return + numbers = (fields[4], fields[6], fields[8]) + if not all(n.isdigit() and len(n) <= 10 for n in numbers): + return + stream, subscriber, tg = map(int, numbers) + if stream > 0xffffffff or not (0 < subscriber <= 0xffffff and 0 < tg <= 0xffffff): + return + previous = streams.get(stream) + if fields[1] == b'END': + # A lost terminator can produce an RX timeout END even for a TX stream. + if previous and previous[0][1:] == (subscriber, tg): + previous[1].cancel() + del streams[stream] + self.changed() + return + if None in streams: + streams[None][1].reset(FBP_STREAM_LIFETIME) + return + row = (fields[2].decode('ascii'), subscriber, tg) + if previous: + if previous[0] == row: + return # A repeated START must not extend the lifetime of a call. + previous[1].cancel() + elif len(streams) >= FBP_STREAMS_PER_LINK: + # Cannot account for every stream. Report unknown, not a false idle. + for _, timer in streams.values(): + timer.cancel() + streams.clear() + stream, row = None, None + streams[stream] = (row, self.clock.callLater(FBP_STREAM_LIFETIME, self._expire, name, stream)) + self.changed() + + def message(self): + snapshot = {name: None if None in streams else [row for row, _ in streams.values()] + for name, streams in self.links.items()} + payload = json.dumps(snapshot, separators=(',', ':')).encode() + return REPORT_OPCODES['FBP_ACTIVITY_SND'] + (payload if len(payload) <= FBP_ACTIVITY_MAX_BYTES else b'{}') def prefixed_system_name(backend_number, system_name): @@ -92,18 +167,42 @@ class ReportMuxClient(NetstringReceiver): self.factory.send_cached(self, REPORT_OPCODES['CONFIG_SND']) elif opcode == REPORT_OPCODES['BRIDGE_REQ']: self.factory.send_cached(self, REPORT_OPCODES['BRIDGE_SND']) + elif opcode == REPORT_OPCODES['FBP_ACTIVITY_REQ'] and data[1:] in (b'1', b'0'): + self.factory.set_activity_subscription(self, data[1:] == b'1') class ReportMuxFactory(Factory): protocol = ReportMuxClient - def __init__(self, allowed_clients=('*',), inventory_backends=()): + def __init__(self, allowed_clients=('*',), inventory_backends=(), clock=reactor): self.allowed_clients = frozenset(allowed_clients) self.inventory_backends = frozenset(inventory_backends) self.clients = set() self._config_by_backend = {} self._bridges_by_backend = {} self._cached = {} + self.clock = clock + self.activity = FBPActivity(clock, self._activity_changed) + self._activity_send = None + + def set_activity_subscription(self, client, enabled): + if getattr(client, 'wants_fbp_activity', False) != enabled: + client.wants_fbp_activity = enabled + if enabled: + self._send(client, self.activity.message()) + + def _activity_changed(self): + # Coalesce fan-out across mesh links; never render/serialize per DMR burst. + if self._activity_send is None and any(getattr(c, 'wants_fbp_activity', False) for c in self.clients): + self._activity_send = self.clock.callLater(0.1, self._publish_activity) + + def _publish_activity(self): + self._activity_send = None + clients = [c for c in self.clients if getattr(c, 'wants_fbp_activity', False)] + if clients: + message = self.activity.message() + for client in clients: + self._send(client, message) def buildProtocol(self, addr): if addr.host in self.allowed_clients or '*' in self.allowed_clients: @@ -126,13 +225,15 @@ class ReportMuxFactory(Factory): def ingest(self, backend_number, message): opcode = message[:1] inventory_only = backend_number in self.inventory_backends - if inventory_only and opcode != REPORT_OPCODES['CONFIG_SND']: - return try: + if inventory_only and opcode != REPORT_OPCODES['CONFIG_SND']: + if opcode == REPORT_OPCODES['BRDG_EVENT']: + self.activity.observe(backend_number, message[1:]) + return if opcode == REPORT_OPCODES['CONFIG_SND']: config = pickle.loads(message[1:]) if inventory_only: - # Inventory is not a second source of calls, bridge state or secrets. + # This source never supplies ordinary call events, bridge state or secrets. fields = ('MODE', 'ENABLED', 'NETWORK_ID', 'TARGET_IP', 'TARGET_PORT', 'ENHANCED_OBP', 'VER', 'REPORT_INTERNAL') config = { @@ -141,10 +242,13 @@ class ReportMuxFactory(Factory): for name, value in config.items() if value.get('MODE') == 'OPENBRIDGE' and value.get('ENABLED') } - self._config_by_backend[backend_number] = prefix_config( - backend_number, - config, - ) + for name, link in config.items(): + if not link.get('REPORT_INTERNAL') and name != 'DATA-GATEWAY': + link['REPORT_FBP_ACTIVITY'] = True + prefixed = prefix_config(backend_number, config) + if inventory_only: + self.activity.set_inventory(self._config_by_backend.get(backend_number, {}), prefixed) + self._config_by_backend[backend_number] = prefixed self._publish_config() elif opcode == REPORT_OPCODES['BRIDGE_SND']: bridges = pickle.loads(message[1:]) @@ -171,6 +275,8 @@ class ReportMuxFactory(Factory): config_removed = self._config_by_backend.pop(backend_number, None) bridges_removed = self._bridges_by_backend.pop(backend_number, None) if config_removed is not None: + if backend_number in self.inventory_backends: + self.activity.set_inventory(config_removed, {}) self._publish_config() if bridges_removed is not None: self._publish_bridges() @@ -286,7 +392,7 @@ if __name__ == '__main__': ) parser.add_argument('--listen-interface', default='127.0.0.1') parser.add_argument('--inventory-backend', action='append', type=parse_backend, - default=[], help='FBP inventory only, as NUMBER,HOST,PORT') + default=[], help='FBP inventory and optional link activity, as NUMBER,HOST,PORT') parser.add_argument('--listen-port', type=int, default=4321) parser.add_argument( '--client', diff --git a/report_sql.py b/report_sql.py index 0029242..1f1ae53 100644 --- a/report_sql.py +++ b/report_sql.py @@ -134,13 +134,15 @@ class reportRelay(NetstringReceiver): self.factory.add_client(self) def connectionLost(self, reason): - self.factory.clients.discard(self) + self.factory.remove_client(self) def stringReceived(self, data): if data[:1] == REPORT_OPCODES['CONFIG_REQ']: self.factory.send_cached(self, REPORT_OPCODES['CONFIG_SND']) elif data[:1] == REPORT_OPCODES['BRIDGE_REQ']: self.factory.send_cached(self, REPORT_OPCODES['BRIDGE_SND']) + elif data[:1] == REPORT_OPCODES['FBP_ACTIVITY_REQ'] and data[1:] in (b'0', b'1'): + self.factory.subscribe_activity(self, data[1:] == b'1') class reportRelayFactory(Factory): @@ -149,6 +151,10 @@ class reportRelayFactory(Factory): def __init__(self): self.clients = set() self._cached = {} + self.activity_clients = set() + self.activity_source = None + self._last_activity = None + self._activity_requested = False def add_client(self, client): self.clients.add(client) @@ -160,8 +166,50 @@ class reportRelayFactory(Factory): if message is not None: self._send(client, message) + def remove_client(self, client): + self.clients.discard(client) + self.subscribe_activity(client, False) + + def subscribe_activity(self, client, enabled): + if enabled and client not in self.activity_clients: + self.activity_clients.add(client) + if self._last_activity is not None: + self._send(client, self._last_activity) + elif self.activity_source is None: + self._send(client, REPORT_OPCODES['FBP_ACTIVITY_SND'] + b'{}') + elif not enabled: + self.activity_clients.discard(client) + self._sync_activity() + + def set_activity_source(self, source, disconnected=False): + if self.activity_source is source: + return + if self._activity_requested and not disconnected: + self.activity_source.sendString(REPORT_OPCODES['FBP_ACTIVITY_REQ'] + b'0') + self.activity_source = source + self._activity_requested = False + self._last_activity = None + if source is None: + for client in tuple(self.activity_clients): + self._send(client, REPORT_OPCODES['FBP_ACTIVITY_SND'] + b'{}') + self._sync_activity() + + def _sync_activity(self): + wanted = bool(self.activity_clients) and self.activity_source is not None + if wanted != self._activity_requested: + self._activity_requested = wanted + if not wanted: + self._last_activity = None + self.activity_source.sendString(REPORT_OPCODES['FBP_ACTIVITY_REQ'] + (b'1' if wanted else b'0')) + def relay(self, message): opcode = message[:1] + if opcode == REPORT_OPCODES['FBP_ACTIVITY_SND']: + if self._activity_requested: + self._last_activity = message + for client in tuple(self.activity_clients): + self._send(client, message) + return if opcode in (REPORT_OPCODES['CONFIG_SND'], REPORT_OPCODES['BRIDGE_SND']): self._cached[opcode] = message for client in tuple(self.clients): @@ -171,7 +219,7 @@ class reportRelayFactory(Factory): try: client.sendString(message) except Exception as err: - self.clients.discard(client) + self.remove_client(client) print('(RELAY) dropping report client after send failure: {}'.format(err)) class reportClient(NetstringReceiver): @@ -185,7 +233,9 @@ class reportClient(NetstringReceiver): if self.relay is not None: self.relay.relay(data) - if data[:1] == REPORT_OPCODES['BRDG_EVENT']: + if data[:1] == REPORT_OPCODES['FBP_ACTIVITY_SND']: + return # Link telemetry is not a call and must never reach the SQL writer. + elif data[:1] == REPORT_OPCODES['BRDG_EVENT']: self.bridgeEvent(data[1:].decode('UTF-8')) elif data[:1] == REPORT_OPCODES['CONFIG_SND']: self.configSend(data[1:]) @@ -249,6 +299,15 @@ class reportClient(NetstringReceiver): def configSend(self,data): self.CONFIG = pickle.loads(data) + if self.relay is not None: + capable = isinstance(self.CONFIG, dict) and any( + isinstance(link, dict) and link.get('REPORT_INVENTORY_ONLY') is True + and link.get('REPORT_FBP_ACTIVITY') is True for link in self.CONFIG.values()) + self.relay.set_activity_source(self if capable else None) + + def connectionLost(self, reason): + if self.relay is not None and self.relay.activity_source is self: + self.relay.set_activity_source(None, disconnected=True) class reportClientFactory(ReconnectingClientFactory): diff --git a/reporting_const.py b/reporting_const.py index 332e515..ca18678 100755 --- a/reporting_const.py +++ b/reporting_const.py @@ -27,4 +27,6 @@ REPORT_OPCODES = { 'BRIDGE_UPD': b'\x05', 'LINK_EVENT': b'\x06', 'BRDG_EVENT': b'\x07', + 'FBP_ACTIVITY_REQ': b'\x08', # ASCII 1 subscribes; 0 unsubscribes + 'FBP_ACTIVITY_SND': b'\x09', # JSON snapshot, never an ordinary call event } diff --git a/tests/test_auxiliary_tools.py b/tests/test_auxiliary_tools.py index 2c251c7..6cc8b57 100644 --- a/tests/test_auxiliary_tools.py +++ b/tests/test_auxiliary_tools.py @@ -1,6 +1,7 @@ import importlib import io import json +import pickle import sys import types import unittest @@ -151,6 +152,96 @@ class AuxiliaryToolTests(unittest.TestCase): relay.add_client(newcomer) self.assertEqual(newcomer.messages, [config, bridge]) + def test_mux_sql_relay_activity_subscription_is_transient_and_not_a_sql_event(self): + self._install_mysql_stub() + import report_sql + from report_mux import ReportMuxFactory + from twisted.internet.task import Clock + from twisted.internet.testing import StringTransport + + ops = report_sql.REPORT_OPCODES + clock = Clock() + mux = ReportMuxFactory(inventory_backends=(3,), clock=clock) + relay = report_sql.reportRelayFactory() + written = [] + sql = report_sql.reportClient(_FakeDB(), types.SimpleNamespace( + callInThread=lambda write, event: (written.append(event), write(event))), relay) + upstream = mux.protocol() + upstream.factory = mux + for end in (sql, upstream): + end.makeConnection(StringTransport()) + + def pump(sender, receiver): + data = sender.transport.value() + sender.transport.clear() + if data: + receiver.dataReceived(data) + return data + + def observer(): + client = relay.protocol() + client.factory = relay + client.makeConnection(StringTransport()) + return client + + normal, console = observer(), observer() + console.dataReceived(b'2:\x081,') + cfg = ops['CONFIG_SND'] + link = dict(MODE='OPENBRIDGE', ENABLED=True) + mux.ingest(1, cfg + pickle.dumps({'MASTER': {'MODE':'MASTER'}})) + pump(upstream, sql) + self.assertEqual(pump(sql, upstream), b'') # Never probe an older/standalone source. + mux.ingest(3, cfg + pickle.dumps({'SWC':link})) + pump(upstream, sql) + self.assertEqual(pump(sql, upstream), b'2:\x081,') + pump(upstream, sql) + for client in (normal, console): + client.transport.clear() + event = ops['BRDG_EVENT'] + b'GROUP VOICE,START,TX,SWC,43,23411,2342690,1,2350' + mux.ingest(3, event) + clock.advance(0.2) + snapshot = pump(upstream, sql) + self.assertIn(b'\x09{"3:SWC":[["TX",2342690,2350]]}', snapshot) + self.assertEqual(console.transport.value(), snapshot) + self.assertEqual(normal.transport.value(), b'') + self.assertFalse(sql.db.committed) + late = observer() + late.transport.clear() + late.dataReceived(b'2:\x081,') + self.assertEqual(late.transport.value(), snapshot) + self.assertEqual(pump(sql, upstream), b'') # Shared upstream subscription. + with redirect_stdout(io.StringIO()): + mux.ingest(1, event.replace(b',SWC,', b',MASTER,')) + pump(upstream, sql) + self.assertTrue(sql.db.committed) + self.assertEqual([e['system'] for e in written], ['1:MASTER']) + self.assertIn(b'1:MASTER', normal.transport.value()) + console.connectionLost(None) + self.assertEqual(pump(sql, upstream), b'') + late.dataReceived(b'2:\x080,') + self.assertEqual(pump(sql, upstream), b'2:\x080,') + late.dataReceived(b'2:\x081,') + self.assertEqual(pump(sql, upstream), b'2:\x081,') + pump(upstream, sql) + late.transport.clear() + sql.connectionLost(None) + self.assertEqual(late.transport.value(), b'3:\x09{},') + newcomer = observer() + newcomer.transport.clear() + newcomer.dataReceived(b'2:\x081,') + self.assertEqual(newcomer.transport.value(), b'3:\x09{},') + upstream.connectionLost(None) + reconnected = mux.protocol() + reconnected.factory = mux + reconnected.makeConnection(StringTransport()) + sql2 = report_sql.reportClient(sql.db, sql.reactor, relay) + sql2.makeConnection(StringTransport()) + pump(reconnected, sql2) + self.assertEqual(pump(sql2, reconnected), b'2:\x081,') + pump(reconnected, sql2) + self.assertEqual(newcomer.transport.value().split(b'\x09')[-1], snapshot.split(b'\x09')[-1]) + self.assertEqual(len(written), 1) + def test_report_factory_isolates_failed_clients_and_targets_replies(self): import hblink diff --git a/tests/test_hdstack_udp.py b/tests/test_hdstack_udp.py index 503da0d..053371a 100644 --- a/tests/test_hdstack_udp.py +++ b/tests/test_hdstack_udp.py @@ -1,3 +1,4 @@ +import json import os import pickle import re @@ -6,14 +7,17 @@ import subprocess import tempfile import time import unittest +from dataclasses import replace from pathlib import Path import hdstack_runtime from tests.harness.fdmr_monitor_compat import consume_config_message +from tests.harness.deterministic import HBPF_SLT_VTERM from reporting_const import REPORT_OPCODES from tests.harness.udp_blackbox import ( HBPF_DATA_SYNC, DependencySandbox, + FbpPeer, FreeDmrProcess, HbpRepeater, HotspotProxyProcess, @@ -58,10 +62,15 @@ class HDStackUdpBlackBoxTests(unittest.TestCase): bridge_config = temporary / 'freedmr-bridge.cfg' bridge_rules = temporary / 'rules.py' proxy_config = temporary / 'proxy.cfg' - main_text = MAIN_CONFIG.replace( - '[EXTERNAL-FBP]\nMODE: OPENBRIDGE\nENABLED: True', - '[EXTERNAL-FBP]\nMODE: OPENBRIDGE\nENABLED: False', - ) + fbp_port = free_udp_port() + external = FbpPeer(fbp_port, 23499) + self.addCleanup(external.close) + # The running bridge builder uses the OBP- naming convention for mesh links. + main_text = MAIN_CONFIG.replace('[EXTERNAL-FBP]', '[OBP-EXTERNAL]') + main_text = main_text.replace('PORT: 62044', f'PORT: {fbp_port}') + main_text = main_text.replace('TARGET_PORT: 62045', f'TARGET_PORT: {external.sockaddr[1]}') + main_text = main_text.replace('PASSPHRASE: external', 'PASSPHRASE: test-passphrase') + main_text = main_text.replace('REPORT: True', 'REPORT: True\nREPORT_INTERFACE: 127.0.0.1') main_text = main_text.replace('TRY_DOWNLOAD: True', 'TRY_DOWNLOAD: False') main_text = main_text.replace('GROUP_HANGTIME: 5', 'GROUP_HANGTIME: 0') main_text = main_text.replace('PORT: 54000', 'PORT: {}'.format(hbp_base)) @@ -225,16 +234,35 @@ class HDStackUdpBlackBoxTests(unittest.TestCase): # The default unit-data hold protects this slot for five seconds. # Test ordinary voice routing only after that hold has expired. time.sleep(5.2) - first.send_dmr( - PacketSpec( - peer_id=first_peer_id, - rf_src=3120001, - dst_id=2350, - slot=2, - ) - ) + external.send_bcka() + external.send_bcve() + external.drain(seconds=0.2) + outbound = PacketSpec(peer_id=first_peer_id, rf_src=3120001, dst_id=2350, slot=2) + report = socket.create_connection(('127.0.0.1', report_base), timeout=3) + self.addCleanup(report.close) + report.sendall(b'2:' + REPORT_OPCODES['FBP_ACTIVITY_REQ'] + b'1,') + + def activity(): + while True: + message = _receive_netstring(report) + if message[:1] == REPORT_OPCODES['FBP_ACTIVITY_SND']: + return json.loads(message[1:]) + + key = '3:OBP-EXTERNAL' + self.assertEqual(activity(), {key:[]}) + first.send_dmr(outbound) received = second.recv(timeout=3.0) self.assertEqual(received.fields['dst_id'], (2350).to_bytes(3, 'big')) + self.assertEqual(external.recv_dmre().fields['dst_id'], received.fields['dst_id']) + self.assertEqual(activity(), {key:[['TX',3120001,2350]]}) + first.send_dmr(replace(outbound, seq=1, frame_type=HBPF_DATA_SYNC, dtype_vseq=HBPF_SLT_VTERM)) + self.assertEqual(activity(), {key:[]}) + inbound = PacketSpec(peer_id=23499, rf_src=3120010, dst_id=91, slot=1, stream_id=0x23499001) + external.send_fbp(inbound, source_server=23499) + self.assertEqual(activity(), {key:[['RX',3120010,91]]}) + external.send_fbp(replace(inbound, seq=1, frame_type=HBPF_DATA_SYNC, dtype_vseq=HBPF_SLT_VTERM), + source_server=23499) + self.assertEqual(activity(), {key:[]}) assignments = [ int(port) @@ -277,6 +305,7 @@ class HDStackUdpBlackBoxTests(unittest.TestCase): '3:OBP-HDSTACK-WORKER-1', '3:OBP-HDSTACK-WORKER-2', '3:OBP-HDSTACK-BRIDGE', + '3:OBP-EXTERNAL', }, ) finally: diff --git a/tests/test_report_mux.py b/tests/test_report_mux.py index 7a68c21..ab11519 100644 --- a/tests/test_report_mux.py +++ b/tests/test_report_mux.py @@ -1,5 +1,6 @@ import os import argparse +import json import pickle import unittest from contextlib import redirect_stdout @@ -9,6 +10,7 @@ from pathlib import Path import report_mux from reporting_const import REPORT_OPCODES from twisted.internet.testing import StringTransport +from twisted.internet.task import Clock from tests.harness.fdmr_monitor_compat import ( consume_bridge_message, consume_config_message, @@ -31,7 +33,7 @@ class ReportMuxTests(unittest.TestCase): self.assertEqual(pickle.loads(client.messages[-1][1:]), { '1:SYSTEM': worker['SYSTEM'], '3:external': dict(MODE='OPENBRIDGE', ENABLED=True, NETWORK_ID=b'1234', REPORT_INTERNAL=False, - REPORT_INVENTORY_ONLY=True)}) + REPORT_INVENTORY_ONLY=True, REPORT_FBP_ACTIVITY=True)}) before = list(client.messages) mux.ingest(3, _report_message('BRIDGE_SND', {'235': []})) mux.ingest(3, REPORT_OPCODES['BRDG_EVENT'] + b'GROUP VOICE,START,RX,external,1,2,3,1,235') @@ -43,6 +45,89 @@ class ReportMuxTests(unittest.TestCase): mux.backend_disconnected(3) self.assertEqual(pickle.loads(client.messages[-1][1:]), {'1:SYSTEM': worker['SYSTEM']}) + def test_opt_in_activity_is_per_link_current_and_never_an_ordinary_call(self): + clock = Clock() + mux = report_mux.ReportMuxFactory(inventory_backends=(3,), clock=clock) + legacy, console = _FakeReportClient(), _FakeReportClient() + mux.add_client(legacy) + mux.add_client(console) + link = dict(MODE='OPENBRIDGE', ENABLED=True, NETWORK_ID=23411) + inventory = {'SWC':link, 'Scotland':link, 'worker':dict(link, REPORT_INTERNAL=True), + 'DATA-GATEWAY':link, 'removed':dict(link, ENABLED=False)} + mux.ingest(3, _report_message('CONFIG_SND', inventory)) + def event(action, direction, name, stream=43, subscriber=2342690, tg=2350): + fields = f'GROUP VOICE,{action},{direction},{name},{stream},23411,{subscriber},1,{tg}' + return REPORT_OPCODES['BRDG_EVENT'] + (fields + (',4.20' if action == 'END' else '')).encode() + for name in inventory: + mux.ingest(3, event('START','RX' if name == 'SWC' else 'TX',name)) + self.assertEqual(len(legacy.messages), 1) + mux.set_activity_subscription(console, True) + def snapshot(): + self.assertEqual(console.messages[-1][:1], REPORT_OPCODES['FBP_ACTIVITY_SND']) + return json.loads(console.messages[-1][1:]) + self.assertEqual(snapshot(), {'3:SWC':[['RX',2342690,2350]], '3:Scotland':[['TX',2342690,2350]]}) + # A refresh is not a new link; an END on one link does not end its neighbour. + mux.ingest(3, _report_message('CONFIG_SND', inventory)) + mux.ingest(3, event('END','RX','SWC')) + mux.ingest(3, event('START','TX','Scotland',44,tg=91)) + clock.advance(0.25) + self.assertEqual(snapshot(), {'3:SWC':[], '3:Scotland':[['TX',2342690,2350], ['TX',2342690,91]]}) + count = len(console.messages) + for other in (event('START','RX','not-configured'), event('START','RX','worker'), + REPORT_OPCODES['BRDG_EVENT'] + b'UNIT DATA,DATA,RX,SWC,11,2,3,1,4'): + mux.ingest(3, other) + clock.advance(0.25) + self.assertEqual(len(console.messages), count) + worker = event('START','RX','worker') + mux.ingest(1, worker) + self.assertEqual(legacy.messages[-1], worker.replace(b',worker,', b',1:worker,')) + self.assertEqual(sum(m[:1] == REPORT_OPCODES['BRDG_EVENT'] for m in legacy.messages), 1) + self.assertFalse(any(m[:1] == REPORT_OPCODES['FBP_ACTIVITY_SND'] for m in legacy.messages)) + clock.advance(181) + clock.advance(0.25) + self.assertEqual(snapshot(), {'3:SWC':[], '3:Scotland':[]}) + mux.backend_disconnected(3) + clock.advance(0.25) + self.assertEqual(snapshot(), {}) + + def test_activity_validation_timeout_and_bounded_fallback(self): + clock = Clock() + mux = report_mux.ReportMuxFactory(inventory_backends=(3,), clock=clock) + def inventory(name): + mux.ingest(3, _report_message('CONFIG_SND', {name: dict(MODE='OPENBRIDGE', ENABLED=True)})) + inventory('A') + def event(fields): + mux.ingest(3, REPORT_OPCODES['BRDG_EVENT'] + fields) + def snapshot(): + return json.loads(mux.activity.message()[1:]) + for fields in (b'GROUP VOICE,START,OTHER,A,4,1,2,1,3', + b'GROUP VOICE,START,RX,A,4294967296,1,2,1,3', + b'GROUP VOICE,START,RX,A,4,1,16777216,1,3', + b'GROUP VOICE,START,RX,A,4,1,2,1,0', + b'GROUP VOICE,START,RX,A,4,1,x'): + event(fields) + self.assertEqual(snapshot(), {'3:A':[]}) + start = b'GROUP VOICE,START,TX,A,4,1,2,1,3,unpublished-tail' + event(start) + event(b'GROUP VOICE,END,TX,A,4,1,2,1,3') + event(b'GROUP VOICE,END,RX,A,4,1,2,1,91,3.50') + self.assertEqual(snapshot(), {'3:A':[['TX',2,3]]}) + # The native stream trimmer can send RX END for a timed-out TX. + event(b'GROUP VOICE,END,RX,A,4,1,2,1,3,3.50') + self.assertEqual(snapshot(), {'3:A':[]}) + event(start) + clock.advance(179) + event(start) + clock.advance(1) + self.assertEqual(snapshot(), {'3:A':[]}) + for i in range(report_mux.FBP_STREAMS_PER_LINK + 1): + event(f'GROUP VOICE,START,RX,A,{i},1,2,1,3'.encode()) + self.assertEqual(snapshot(), {'3:A':None}) + clock.advance(report_mux.FBP_STREAM_LIFETIME) + self.assertEqual(snapshot(), {'3:A':[]}) + inventory('X' * report_mux.FBP_ACTIVITY_MAX_BYTES) + self.assertEqual(snapshot(), {}) + def test_merges_config_and_disambiguates_colliding_system_names(self): mux = report_mux.ReportMuxFactory() client = _FakeReportClient()