Update transmit.py check for tx freq 3rd harmonic rx

master-bh
Alan Johnston 2 months ago committed by GitHub
parent c7f117d873
commit da949a287e
No known key found for this signature in database
GPG Key ID: B5690EEEBB952194

@ -714,6 +714,7 @@ if __name__ == "__main__":
if len(config) > 6:
txf = float(config[6])
tx = "{:.4f}".format(txf)
txrf = 0
if (mode == 'e'):
if (txf > 420.0) and (txf < 450.0):
txrf = (txf - 290.0) # - 0.1 # Cross Band Repeater mode transmit frequency in 2m band
@ -731,6 +732,16 @@ if __name__ == "__main__":
rxf = float(config[7])
rx = "{:.4f}".format(rxf)
print(rx)
if abs(rxf - 3 * txrf) < 10.0:
txrf = txrf + 0.02
txr = "{:.4f}".format(txrf)
print("Adjusting Repeater TX frequency to avoid 3rd harmonic RX")
print("Transmit frequency: ",txr)
if abs(rxf - 3 * txf) < 10.0:
txf = txf + 0.02
tx = "{:.4f}".format(txf)
print("Adjusting TX frequency to avoid 3rd harmonic RX")
print("Transmit frequency: ",tx)
if len(config) > 8:
if config[8] == 'y' or config[8] == 'yes':
hab_mode = True