fix: align OpenBridge and bridge routing with legacy server

Match bridge_master/hblink behaviour: BRIDGES table iteration for
to_target, OBP VTERM/_fin timing, stream seq/crc handling, and
document related GLOBAL options.
pull/4/head
Rodrigo Pérez 6 months ago
parent d1696d6016
commit 160f1ae802

@ -17,6 +17,9 @@ GLOBAL:
PASS_SECURITY: "<set-in-adn-server.yaml>"
USERS_PASS: user_passwords.json
HASH_ENCRYPT: encryption_key.secret
# Multi-OBP mesh hub: when true, inbound peer BCSQ does not block bridge TX from the mesh-designated source OBP
# (see _obp_mesh_first). Set false for strict legacy routerOBP behavior.
OBP_BRIDGE_MESH_OWNER_BYPASS_BCSQ: true
REPORTS:
REPORT: true

@ -72,6 +72,13 @@ class BridgeUseCases:
self._report_factory = report_factory
self._on_bridge_deactivated = on_bridge_deactivated # (system_name: str) -> None; legacy disconnectedVoice
self._send_bcsq = send_bcsq # (system_name, tgid, stream_id) -> None; legacy OBP send_bcsq from router
# (stream_id, tgid_bytes) -> {"owner": system_name, "last": monotonic}; cross-OBP first leg (bridge_master race)
self._obp_mesh_first: dict[tuple[bytes, bytes], dict[str, Any]] = {}
def _obp_prune_mesh_first(self, now_m: float) -> None:
stale = [k for k, v in self._obp_mesh_first.items() if now_m - float(v.get("last", 0)) > 180.0]
for k in stale:
self._obp_mesh_first.pop(k, None)
def get_bridges(self) -> dict[str, list[dict[str, Any]]]:
"""Return current BRIDGES."""
@ -343,6 +350,15 @@ class BridgeUseCases:
pass
to_remove.append(stream_id)
for stream_id in to_remove:
st_rm = obp_streams.get(stream_id) or {}
tgid_rm = st_rm.get("TGID", b"\x00\x00\x00")
self._obp_mesh_first.pop((stream_id, tgid_rm), None)
_syscfg = systems_cfg.get(system_name, {})
_bmap = _syscfg.get("_bcsq")
if isinstance(_bmap, dict):
for _tgid_k, _sid in list(_bmap.items()):
if _sid == stream_id:
_bmap.pop(_tgid_k, None)
obp_streams.pop(stream_id, None)
continue
for slot in (1, 2):
@ -438,6 +454,70 @@ class BridgeUseCases:
"""Check ID against ACL. Legacy acl_check."""
return self._router.acl_check(id_val, acl)
def _ensure_obp_source_for_tg(
self,
system_name: str,
bridge_key: str,
dst_id_b: bytes,
dst_int: int,
) -> None:
"""Ensure this OBP has an ACTIVE source row for TG (TS1) in main and #reflector bridges.
remove_bridge_system / BRIDGERESET sets all rows for a system to ACTIVE False. Local MASTER
traffic still matches MASTER source rows; inbound OBP traffic needs these OBP rows re-enabled
or added (e.g. new OBP in config after bridge was built).
Same TG range as make_single_bridge OBP entries.
"""
systems_cfg = self._config.get("SYSTEMS", {})
if systems_cfg.get(system_name, {}).get("MODE") != "OPENBRIDGE":
return
if not systems_cfg.get(system_name, {}).get("ENABLED", True):
return
if not (79 <= dst_int < 9990 or dst_int > 9999):
return
bridges = self._router.get_bridges()
now = time.time()
def _tgid_match(entry: dict[str, Any]) -> bool:
tg = entry.get("TGID")
if tg == dst_id_b:
return True
try:
return int_id(tg or b"\x00\x00\x00") == dst_int
except (TypeError, ValueError):
return False
def _patch(entries: list[dict[str, Any]]) -> None:
for e in entries:
if e.get("SYSTEM") != system_name:
continue
if e.get("TS") != 1:
continue
if not _tgid_match(e):
continue
if not e.get("ACTIVE"):
e["ACTIVE"] = True
return
entries.append(
{
"SYSTEM": system_name,
"TS": 1,
"TGID": dst_id_b,
"ACTIVE": True,
"TIMEOUT": "",
"TO_TYPE": "NONE",
"OFF": [],
"ON": [],
"RESET": [],
"TIMER": now,
}
)
for key in (bridge_key, "#" + bridge_key):
if key not in bridges:
continue
_patch(bridges[key])
def make_single_bridge(
self,
_tgid: bytes | int,
@ -1080,8 +1160,20 @@ class BridgeUseCases:
dtype_vseq: int,
stream_id: bytes,
data: bytes,
*,
obp_use_parsed: bool = False,
obp_hops: bytes = b"",
obp_source_server: bytes | None = None,
obp_ber: bytes = b"\x00",
obp_rssi: bytes = b"\x00",
obp_source_rptr: bytes = b"\x00\x00\x00\x00",
) -> None:
"""Called by UDP MASTER when DMRD is received. Forward to other systems in same bridge (to_target)."""
"""Called by UDP when DMRD is received. Forward to other systems in same bridge (to_target).
Legacy `hblink.dmrd_received` passes `_hash,_hops,_source_server,_ber,_rssi,_source_rptr` after
parsing OPENBRIDGE DMRD v1 / DMRE (`hblink.py` ~309–416, ~592–596). When `obp_use_parsed` is True,
the OBP path uses those values (1:1 with `bridge.py` `routerOBP.dmrd_received` → `send_system`).
"""
if not self._send_to_system:
return
# Legacy bridge_master 3080–3085: private call to ID 4000 only disconnects dynamics; do not route as PC.
@ -1119,28 +1211,29 @@ class BridgeUseCases:
self.make_single_bridge(dst_id, system_name, slot, float(tmout))
self.apply_static_tg_to_bridge(dst_int)
bridges = self._router.get_bridges()
# Legacy bridge_master 3198–3218: forward to current bridge (tgid) and reflector bridge (#tgid)
entries = list(bridges.get(bridge_key, [])) + list(bridges.get("#" + bridge_key, []))
# Legacy: only forward if source rule matches (system, TGID, slot, ACTIVE True) — bridge.py 349, 664
# Legacy bridge_master routerOBP ~2413-2418: scan every BRIDGES[_bridge] table; forward only within
# a table that contains a matching ACTIVE source row (not a flat merge of TG + #TG only).
dst_id_b = dst_id if isinstance(dst_id, bytes) and len(dst_id) >= 3 else bytes_3(dst_int)
has_source = any(
entry.get("SYSTEM") == system_name
and entry.get("TS") == bridge_match_slot
and entry.get("ACTIVE")
and (entry.get("TGID") == dst_id_b or int_id(entry.get("TGID") or b"\x00\x00\x00") == dst_int)
for entry in entries
)
def _row_is_active_source(row: dict[str, Any]) -> bool:
return bool(
row.get("SYSTEM") == system_name
and row.get("TS") == bridge_match_slot
and row.get("ACTIVE")
and (
row.get("TGID") == dst_id_b
or int_id(row.get("TGID") or b"\x00\x00\x00") == dst_int
)
)
if source_is_obp:
self._ensure_obp_source_for_tg(system_name, bridge_key, dst_id_b, dst_int)
bridges = self._router.get_bridges()
has_source = any(_row_is_active_source(e) for elist in bridges.values() for e in elist)
if not has_source and systems_cfg.get(system_name, {}).get("MODE") == "MASTER":
self.options_config_for_system(system_name)
bridges = self._router.get_bridges()
entries = list(bridges.get(bridge_key, [])) + list(bridges.get("#" + bridge_key, []))
has_source = any(
entry.get("SYSTEM") == system_name
and entry.get("TS") == bridge_match_slot
and entry.get("ACTIVE")
and (entry.get("TGID") == dst_id_b or int_id(entry.get("TGID") or b"\x00\x00\x00") == dst_int)
for entry in entries
)
has_source = any(_row_is_active_source(e) for elist in bridges.values() for e in elist)
if not has_source:
logger.debug(
"(ROUTER) No matching source rule for TG %s from %s slot %s (ACTIVE), not forwarding",
@ -1180,37 +1273,29 @@ class BridgeUseCases:
)
obp_streams[stream_id]["LOOPLOG"] = True
return
# First OBP: only the OBP that received the stream first (min 1ST) forwards; others drop
hr_times = {}
if obp_streams is not None and stream_id in obp_streams and "1ST" in obp_streams[stream_id]:
hr_times[system_name] = obp_streams[stream_id]["1ST"]
dst_id_b = dst_id if isinstance(dst_id, bytes) and len(dst_id) >= 3 else bytes_3(int_id(dst_id))
for other_name, proto in (protocols or {}).items():
if other_name == system_name:
continue
if systems_cfg.get(other_name, {}).get("MODE") != "OPENBRIDGE":
continue
other_streams = getattr(proto, "_obp_streams", None)
if other_streams is None or stream_id not in other_streams:
continue
st = other_streams[stream_id]
if "1ST" not in st or (st.get("TGID") or b"") != dst_id_b:
continue
hr_times[other_name] = st["1ST"]
if hr_times:
first_system = min(hr_times, key=hr_times.get)
if first_system != system_name:
if obp_streams is not None and stream_id in obp_streams and not obp_streams[stream_id].get("LOOPLOG"):
logger.debug(
"(%s) OBP *LoopControl* FIRST OBP %s, STREAM ID: %s, TG %s, IGNORE THIS SOURCE",
system_name, first_system, int_id(stream_id), int_id(dst_id),
)
obp_streams[stream_id]["LOOPLOG"] = True
if self._send_bcsq and systems_cfg.get(system_name, {}).get("ENHANCED_OBP"):
if obp_streams is not None and stream_id in obp_streams and "_bcsq" not in obp_streams[stream_id]:
self._send_bcsq(system_name, dst_id, stream_id)
obp_streams[stream_id]["_bcsq"] = True
return
# First OBP: single server-wide winner per (stream_id, TGID). Per-leg 1ST compare can both-forward on
# the first reactor tick before peer _obp_streams exists → duplicate TX → mesh BCSQ on every link.
_mesh_key = (stream_id, dst_id_b)
_now_m = time.monotonic()
self._obp_prune_mesh_first(_now_m)
_mf = self._obp_mesh_first.get(_mesh_key)
if _mf is None:
_mf = {"owner": system_name, "last": _now_m}
self._obp_mesh_first[_mesh_key] = _mf
elif _mf.get("owner") != system_name:
if obp_streams is not None and stream_id in obp_streams and not obp_streams[stream_id].get("LOOPLOG"):
logger.debug(
"(%s) OBP *LoopControl* FIRST OBP (mesh) %s, STREAM ID: %s, TG %s, IGNORE THIS SOURCE",
system_name, _mf.get("owner"), int_id(stream_id), int_id(dst_id),
)
obp_streams[stream_id]["LOOPLOG"] = True
if self._send_bcsq and systems_cfg.get(system_name, {}).get("ENHANCED_OBP"):
if obp_streams is not None and stream_id in obp_streams and "_bcsq" not in obp_streams[stream_id]:
self._send_bcsq(system_name, dst_id, stream_id)
obp_streams[stream_id]["_bcsq"] = True
return
else:
_mf["last"] = _now_m
# Legacy bridge.py: BRDG_EVENT for report/monitor (GROUP VOICE START/END RX/TX)
if self._report_factory and hasattr(self._report_factory, "send_bridge_event"):
try:
@ -1246,13 +1331,36 @@ class BridgeUseCases:
_bits = data[15] if len(data) > 15 else 0
protocols = self._get_protocols() if self._get_protocols else {}
src_proto = protocols.get(system_name) if protocols else None
# Legacy routerHBP: _ber = _data[53:54]; _rssi = _data[54:55]
# Legacy routerOBP: _ber = b'\x00'; _rssi = b'\x00' (from dmrd_received defaults)
if source_is_obp:
# Legacy `bridge.py` `routerOBP.dmrd_received` forwards `_hops,_ber,_rssi,_source_server,_source_rptr`
# exactly as received from `hblink` (`bridge.py` ~486). Values are set in `hblink`:
# - DMRD v1 OBP: SERVER_ID, zeros rptr, empty hops (`hblink.py` ~338–345)
# - DMRE v5: packet fields + incremented hops (`hblink.py` ~592–596)
# Legacy `bridge_master` `routerHBP.dmrd_received`: ber/rssi from payload, SERVER_ID + peer as rptr (~2936–2940).
if source_is_obp and obp_use_parsed:
_hops = obp_hops
_ber = obp_ber
_rssi = obp_rssi
_sid = self._config.get("GLOBAL", {}).get("SERVER_ID")
if obp_source_server is not None:
_source_server = obp_source_server
elif isinstance(_sid, bytes) and len(_sid) >= 4:
_source_server = _sid
elif _sid is not None:
_source_server = bytes_4(int(_sid) & 0xFFFFFFFF)
else:
_source_server = b"\x00\x00\x00\x00"
_source_rptr = obp_source_rptr
elif source_is_obp:
_ber = b"\x00"
_rssi = b"\x00"
_hops = b""
_source_server = b"\x00\x00\x00\x00"
_sid = self._config.get("GLOBAL", {}).get("SERVER_ID")
if isinstance(_sid, bytes) and len(_sid) >= 4:
_source_server = _sid
elif _sid is not None:
_source_server = bytes_4(int(_sid) & 0xFFFFFFFF)
else:
_source_server = b"\x00\x00\x00\x00"
_source_rptr = b"\x00\x00\x00\x00"
else:
_ber = data[53:54] if len(data) > 53 else b"\x00"
@ -1276,197 +1384,288 @@ class BridgeUseCases:
source_lc = st.get(slot, {}).get("RX_LC")
if not source_lc or len(source_lc) < 9:
source_lc = b"\x00\x00\x20" + dst_id_b + rf_src
# Legacy bridge_master to_target: _sysIgnore — dedupe OBP (SYSTEM, TS) per packet across
# multiple to_target passes (current TG + reflector + other bridges). We merge those
# lists into one `entries` loop, so the same OpenBridge can appear twice (e.g. TG + #TG)
# and would get duplicate sends → echo/loops without this.
# Legacy bridge_master routerOBP: _sysIgnore accumulates across each to_target(BRIDGES[_bridge])
# pass; dedupe (SYSTEM, TS) for OpenBridge targets so the same leg is not sent twice per packet.
sys_ignore_obp: set[tuple[str, int]] = set()
forwarded = []
for entry in entries:
if entry.get("SYSTEM") == system_name:
continue
if not entry.get("ACTIVE", False):
_g = self._config.get("GLOBAL", {})
_bypass_bcsq_mesh_owner = _g.get("OBP_BRIDGE_MESH_OWNER_BYPASS_BCSQ", True)
_obp_mesh_forward_owner = False
if source_is_obp and _bypass_bcsq_mesh_owner:
_om = self._obp_mesh_first.get((stream_id, dst_id_b))
_obp_mesh_forward_owner = _om is not None and _om.get("owner") == system_name
for _bridge_table_name, _bridge_rows in list(bridges.items()):
if not any(_row_is_active_source(r) for r in _bridge_rows):
continue
if not systems_cfg.get(entry["SYSTEM"], {}).get("ENABLED", True):
continue
_target_system = systems_cfg.get(entry["SYSTEM"], {})
target_mode = _target_system.get("MODE")
tgt_proto = protocols.get(entry["SYSTEM"]) if protocols else None
_target_status = getattr(tgt_proto, "STATUS", None) if tgt_proto else None
if target_mode == "OPENBRIDGE":
# ── Exact port of legacy bridge.py OBP target (lines 355-401 / 672-718) ──
entry_ts_obp = entry.get("TS")
if entry_ts_obp is None:
entry_ts_obp = 1
_obp_key = (entry["SYSTEM"], int(entry_ts_obp))
if _obp_key in sys_ignore_obp:
for entry in _bridge_rows:
if entry.get("SYSTEM") == system_name:
continue
sys_ignore_obp.add(_obp_key)
target_tgid = entry.get("TGID")
if isinstance(target_tgid, int):
target_tgid = bytes_3(target_tgid)
if _target_status is not None:
if stream_id not in _target_status:
_target_status[stream_id] = {
"START": pkt_time,
"CONTENTION": False,
"RFS": rf_src,
"TGID": dst_id_b,
}
dst_lc = source_lc[0:3] + target_tgid + rf_src
_target_status[stream_id]["H_LC"] = bptc.encode_header_lc(dst_lc)
_target_status[stream_id]["T_LC"] = bptc.encode_terminator_lc(dst_lc)
_target_status[stream_id]["EMB_LC"] = bptc.encode_emblc(dst_lc)
if not entry.get("ACTIVE", False):
continue
if not systems_cfg.get(entry["SYSTEM"], {}).get("ENABLED", True):
continue
_target_system = systems_cfg.get(entry["SYSTEM"], {})
target_mode = _target_system.get("MODE")
tgt_proto = protocols.get(entry["SYSTEM"]) if protocols else None
_target_status = getattr(tgt_proto, "STATUS", None) if tgt_proto else None
if target_mode == "OPENBRIDGE":
# ── bridge_master.routerOBP.to_target OPENBRIDGE branch (~1850-1959) ──
entry_ts_obp = entry.get("TS")
if entry_ts_obp is None:
entry_ts_obp = 1
_obp_key = (entry["SYSTEM"], int(entry_ts_obp))
if _obp_key in sys_ignore_obp:
continue
sys_ignore_obp.add(_obp_key)
target_tgid = entry.get("TGID")
if isinstance(target_tgid, int):
target_tgid = bytes_3(target_tgid)
# If target has quenched us, don't send (~1856-1859). Mesh hub: peers often BCSQ every leg on
# duplicate paths; bypass for the server-designated forward OBP so TX continues to remotes.
_bcsq_map = _target_system.get("_bcsq")
if (
not _obp_mesh_forward_owner
and isinstance(_bcsq_map, dict)
and dst_id_b in _bcsq_map
and _bcsq_map[dst_id_b] == stream_id
):
logger.debug(
"(%s) OBP skip (BCSQ): target=%s TGID=%s stream=%s",
system_name,
entry["SYSTEM"],
int_id(dst_id_b),
int_id(stream_id),
)
continue
# If target has missed keepalives (ENHANCED_OBP), don't send (~1861-1863)
if _target_system.get("ENHANCED_OBP") and (
"_bcka" not in _target_system or _target_system["_bcka"] < pkt_time - 60
):
logger.debug(
"(%s) OBP skip (BCKA stale/missing): target=%s _bcka=%s pkt_time=%s",
system_name,
entry["SYSTEM"],
_target_system.get("_bcka"),
pkt_time,
)
continue
# Talkgroup ACL (global + per-system TG1) (~1865-1873)
_global_cfg = self._config.get("GLOBAL", {})
if _global_cfg.get("USE_ACL"):
if not self.acl_check(target_tgid, _global_cfg.get("TG1_ACL", (True, []))):
logger.debug(
"(%s) OBP skip (global ACL): target=%s TGID=%s",
system_name,
entry["SYSTEM"],
int_id(target_tgid),
)
continue
if not self.acl_check(target_tgid, _target_system.get("TG1_ACL", (True, []))):
logger.debug(
"(%s) OBP skip (system ACL): target=%s TGID=%s",
system_name,
entry["SYSTEM"],
int_id(target_tgid),
)
continue
if _target_status is not None:
if stream_id not in _target_status:
_target_status[stream_id] = {
"START": pkt_time,
"CONTENTION": False,
"RFS": rf_src,
"TGID": dst_id_b,
"RX_PEER": peer_id,
"EMB_LC": {1: b"\x00", 2: b"\x00", 3: b"\x00", 4: b"\x00"},
"H_LC": b"\x00",
"T_LC": b"\x00",
}
try:
dst_lc = source_lc[0:3] + target_tgid + rf_src
except Exception:
logger.exception("(to_target) caught exception")
_target_status[stream_id]["LAST"] = pkt_time
return
_target_status[stream_id]["H_LC"] = bptc.encode_header_lc(dst_lc)
_target_status[stream_id]["T_LC"] = bptc.encode_terminator_lc(dst_lc)
_target_status[stream_id]["EMB_LC"] = bptc.encode_emblc(dst_lc)
logger.debug(
"(%s) Conference Bridge: %s, Call Bridged to OBP System: %s TS: %s, TGID: %s",
system_name, _bridge_table_name, entry["SYSTEM"], entry.get("TS", 1), int_id(target_tgid),
)
if self._report_factory and hasattr(self._report_factory, "send_bridge_event"):
try:
self._report_factory.send_bridge_event(
"GROUP VOICE,START,TX,{},{},{},{},{},{}".format(
entry["SYSTEM"], int_id(stream_id), int_id(peer_id), int_id(rf_src), entry.get("TS", 1), int_id(target_tgid)
)
)
except Exception:
pass
if "EMB_LC" not in _target_status[stream_id]:
try:
dst_lc = source_lc[0:3] + target_tgid + rf_src
_target_status[stream_id]["EMB_LC"] = bptc.encode_emblc(dst_lc)
except Exception:
logger.exception("(to_target) caught exception while creating EMB_LC")
return
if "H_LC" not in _target_status[stream_id]:
try:
dst_lc = source_lc[0:3] + target_tgid + rf_src
_target_status[stream_id]["H_LC"] = bptc.encode_header_lc(dst_lc)
except Exception:
logger.exception("(to_target) caught exception while creating H_LC")
return
if "T_LC" not in _target_status[stream_id]:
try:
dst_lc = source_lc[0:3] + target_tgid + rf_src
_target_status[stream_id]["T_LC"] = bptc.encode_terminator_lc(dst_lc)
except Exception:
logger.exception("(to_target) caught exception while creating T_LC")
return
_target_status[stream_id]["LAST"] = pkt_time
_tmp_bits = _bits & ~(1 << 7)
_tmp_data = b"".join([data[:8], target_tgid, data[11:15], bytes([_tmp_bits]), data[16:20]])
dmrbits = bitarray(endian="big")
dmrbits.frombytes(dmrpkt)
if frame_type == HBPF_DATA_SYNC and dtype_vseq == HBPF_SLT_VHEAD:
dmrbits = _target_status[stream_id]["H_LC"][0:98] + dmrbits[98:166] + _target_status[stream_id]["H_LC"][98:197]
elif frame_type == HBPF_DATA_SYNC and dtype_vseq == HBPF_SLT_VTERM:
dmrbits = _target_status[stream_id]["T_LC"][0:98] + dmrbits[98:166] + _target_status[stream_id]["T_LC"][98:197]
if self._report_factory and hasattr(self._report_factory, "send_bridge_event"):
try:
call_duration = pkt_time - _target_status[stream_id].get("START", pkt_time)
self._report_factory.send_bridge_event(
"GROUP VOICE,END,TX,{},{},{},{},{},{},{:.2f}".format(
entry["SYSTEM"], int_id(stream_id), int_id(peer_id), int_id(rf_src), entry.get("TS", 1), int_id(target_tgid), call_duration
)
)
except Exception:
pass
elif dtype_vseq in (1, 2, 3, 4):
dmrbits = dmrbits[0:116] + _target_status[stream_id]["EMB_LC"][dtype_vseq] + dmrbits[148:264]
dmrpkt_out = dmrbits.tobytes()
_tmp_data = b"".join([_tmp_data, dmrpkt_out])
else:
_tmp_bits = _bits & ~(1 << 7)
_tmp_data = b"".join([data[:8], target_tgid, data[11:15], bytes([_tmp_bits]), data[16:20]])
_tmp_data = b"".join([_tmp_data, dmrpkt])
try:
self._send_to_system(
entry["SYSTEM"], _tmp_data,
_hops=_hops, _ber=_ber, _rssi=_rssi,
_source_server=_source_server, _source_rptr=_source_rptr,
)
forwarded.append(entry["SYSTEM"])
except Exception as e:
logger.warning("(ROUTER) send_to_system %s failed: %s", entry.get("SYSTEM"), e)
else:
# ── Exact port of legacy bridge.py HBP target (lines 403-486 / 720-803) ──
entry_ts = entry.get("TS")
if entry_ts is None:
continue
entry_tgid_b = entry.get("TGID")
if isinstance(entry_tgid_b, int):
entry_tgid_b = bytes_3(entry_tgid_b)
if _target_status is None or entry_ts not in _target_status:
continue
_ts_st = _target_status[entry_ts]
# Contention handling (exact port of legacy bridge.py 413-432 / 730-745)
if (entry_tgid_b != _ts_st.get("RX_TGID", b"\x00\x00\x00")) and ((pkt_time - _ts_st.get("RX_TIME", 0)) < float(_target_system.get("GROUP_HANGTIME", 0))):
continue
if (entry_tgid_b != _ts_st.get("TX_TGID", b"\x00\x00\x00")) and ((pkt_time - _ts_st.get("TX_TIME", 0)) < float(_target_system.get("GROUP_HANGTIME", 0))):
continue
if (entry_tgid_b == _ts_st.get("RX_TGID", b"\x00\x00\x00")) and ((pkt_time - _ts_st.get("RX_TIME", 0)) < STREAM_TO):
continue
if (entry_tgid_b == _ts_st.get("TX_TGID", b"\x00\x00\x00")) and (rf_src != _ts_st.get("TX_RFS", b"")) and ((pkt_time - _ts_st.get("TX_TIME", 0)) < STREAM_TO):
continue
# New stream detection — legacy OBP uses _target_status[TS]['TX_STREAM_ID'], legacy HBP uses self.STATUS[_slot]['RX_STREAM_ID']
if source_is_obp:
_is_new_stream = (_ts_st.get("TX_STREAM_ID") != stream_id)
else:
src_status = getattr(src_proto, "STATUS", None) if src_proto else None
_is_new_stream = (src_status.get(slot, {}).get("RX_STREAM_ID") if src_status else b"") != stream_id
if _is_new_stream:
_ts_st["TX_START"] = pkt_time
_ts_st["TX_TGID"] = entry_tgid_b
_ts_st["TX_STREAM_ID"] = stream_id
_ts_st["TX_RFS"] = rf_src
_ts_st["TX_PEER"] = peer_id
dst_lc = source_lc[0:3] + entry_tgid_b + rf_src
_ts_st["TX_H_LC"] = bptc.encode_header_lc(dst_lc)
_ts_st["TX_T_LC"] = bptc.encode_terminator_lc(dst_lc)
_ts_st["TX_EMB_LC"] = bptc.encode_emblc(dst_lc)
logger.info(
"(%s) Conference Bridge: %s, Call Bridged to OBP System: %s TS: %s, TGID: %s",
system_name, bridge_key, entry["SYSTEM"], entry.get("TS", 1), int_id(target_tgid),
"(%s) Conference Bridge: %s, Call Bridged to HBP System: %s TS: %s, TGID: %s",
system_name, _bridge_table_name, entry["SYSTEM"], entry_ts, int_id(entry_tgid_b),
)
if self._report_factory and hasattr(self._report_factory, "send_bridge_event"):
try:
self._report_factory.send_bridge_event(
"GROUP VOICE,START,TX,{},{},{},{},{},{}".format(
entry["SYSTEM"], int_id(stream_id), int_id(peer_id), int_id(rf_src), entry.get("TS", 1), int_id(target_tgid)
entry["SYSTEM"], int_id(stream_id), int_id(peer_id), int_id(rf_src), entry_ts, int_id(entry_tgid_b)
)
)
except Exception:
pass
_target_status[stream_id]["LAST"] = pkt_time
_tmp_bits = _bits & ~(1 << 7)
_tmp_data = b"".join([data[:8], target_tgid, data[11:15], bytes([_tmp_bits]), data[16:20]])
_ts_st["TX_TIME"] = pkt_time
_ts_st["TX_TYPE"] = dtype_vseq
# Slot bit rewrite (legacy bridge.py 457-460 / 770-773)
_src_entry_ts = slot
if _src_entry_ts != entry_ts:
_tmp_bits = _bits ^ (1 << 7)
else:
_tmp_bits = _bits
_tmp_data = b"".join([data[:8], entry_tgid_b, data[11:15], bytes([_tmp_bits]), data[16:20]])
# LC rewrite (exact port of legacy bridge.py 468-482 / 781-799)
dmrbits = bitarray(endian="big")
dmrbits.frombytes(dmrpkt)
if frame_type == HBPF_DATA_SYNC and dtype_vseq == HBPF_SLT_VHEAD:
dmrbits = _target_status[stream_id]["H_LC"][0:98] + dmrbits[98:166] + _target_status[stream_id]["H_LC"][98:197]
dmrbits = _ts_st["TX_H_LC"][0:98] + dmrbits[98:166] + _ts_st["TX_H_LC"][98:197]
elif frame_type == HBPF_DATA_SYNC and dtype_vseq == HBPF_SLT_VTERM:
dmrbits = _target_status[stream_id]["T_LC"][0:98] + dmrbits[98:166] + _target_status[stream_id]["T_LC"][98:197]
dmrbits = _ts_st["TX_T_LC"][0:98] + dmrbits[98:166] + _ts_st["TX_T_LC"][98:197]
if self._report_factory and hasattr(self._report_factory, "send_bridge_event"):
try:
call_duration = pkt_time - _target_status[stream_id].get("START", pkt_time)
call_duration = pkt_time - _ts_st.get("TX_START", pkt_time)
self._report_factory.send_bridge_event(
"GROUP VOICE,END,TX,{},{},{},{},{},{},{:.2f}".format(
entry["SYSTEM"], int_id(stream_id), int_id(peer_id), int_id(rf_src), entry.get("TS", 1), int_id(target_tgid), call_duration
entry["SYSTEM"], int_id(stream_id), int_id(peer_id), int_id(rf_src), entry_ts, int_id(entry_tgid_b), call_duration
)
)
except Exception:
pass
elif dtype_vseq in (1, 2, 3, 4):
dmrbits = dmrbits[0:116] + _target_status[stream_id]["EMB_LC"][dtype_vseq] + dmrbits[148:264]
try:
dmrbits = dmrbits[0:116] + _ts_st["TX_EMB_LC"][dtype_vseq] + dmrbits[148:264]
except Exception:
pass
dmrpkt_out = dmrbits.tobytes()
# bridge_master.routerOBP.to_target HBP branch: _tmp_data + dmrpkt only (~2041-2042);
# HBP source adds BER/RSSI from payload (bridge.py routerHBP ~800).
if source_is_obp:
_tmp_data = b"".join([_tmp_data, dmrpkt_out])
else:
_tmp_data = b"".join([_tmp_data, dmrpkt_out])
else:
_tmp_bits = _bits & ~(1 << 7)
_tmp_data = b"".join([data[:8], target_tgid, data[11:15], bytes([_tmp_bits]), data[16:20]])
_tmp_data = b"".join([_tmp_data, dmrpkt])
try:
self._send_to_system(
entry["SYSTEM"], _tmp_data,
_hops=_hops, _ber=_ber, _rssi=_rssi,
_source_server=_source_server, _source_rptr=_source_rptr,
)
forwarded.append(entry["SYSTEM"])
except Exception as e:
logger.warning("(ROUTER) send_to_system %s failed: %s", entry.get("SYSTEM"), e)
else:
# ── Exact port of legacy bridge.py HBP target (lines 403-486 / 720-803) ──
entry_ts = entry.get("TS")
if entry_ts is None:
continue
entry_tgid_b = entry.get("TGID")
if isinstance(entry_tgid_b, int):
entry_tgid_b = bytes_3(entry_tgid_b)
if _target_status is None or entry_ts not in _target_status:
continue
_ts_st = _target_status[entry_ts]
# Contention handling (exact port of legacy bridge.py 413-432 / 730-745)
if (entry_tgid_b != _ts_st.get("RX_TGID", b"\x00\x00\x00")) and ((pkt_time - _ts_st.get("RX_TIME", 0)) < float(_target_system.get("GROUP_HANGTIME", 0))):
continue
if (entry_tgid_b != _ts_st.get("TX_TGID", b"\x00\x00\x00")) and ((pkt_time - _ts_st.get("TX_TIME", 0)) < float(_target_system.get("GROUP_HANGTIME", 0))):
continue
if (entry_tgid_b == _ts_st.get("RX_TGID", b"\x00\x00\x00")) and ((pkt_time - _ts_st.get("RX_TIME", 0)) < STREAM_TO):
continue
if (entry_tgid_b == _ts_st.get("TX_TGID", b"\x00\x00\x00")) and (rf_src != _ts_st.get("TX_RFS", b"")) and ((pkt_time - _ts_st.get("TX_TIME", 0)) < STREAM_TO):
continue
# New stream detection — legacy OBP uses _target_status[TS]['TX_STREAM_ID'], legacy HBP uses self.STATUS[_slot]['RX_STREAM_ID']
if source_is_obp:
_is_new_stream = (_ts_st.get("TX_STREAM_ID") != stream_id)
else:
src_status = getattr(src_proto, "STATUS", None) if src_proto else None
_is_new_stream = (src_status.get(slot, {}).get("RX_STREAM_ID") if src_status else b"") != stream_id
if _is_new_stream:
_ts_st["TX_START"] = pkt_time
_ts_st["TX_TGID"] = entry_tgid_b
_ts_st["TX_STREAM_ID"] = stream_id
_ts_st["TX_RFS"] = rf_src
_ts_st["TX_PEER"] = peer_id
dst_lc = source_lc[0:3] + entry_tgid_b + rf_src
_ts_st["TX_H_LC"] = bptc.encode_header_lc(dst_lc)
_ts_st["TX_T_LC"] = bptc.encode_terminator_lc(dst_lc)
_ts_st["TX_EMB_LC"] = bptc.encode_emblc(dst_lc)
logger.info(
"(%s) Conference Bridge: %s, Call Bridged to HBP System: %s TS: %s, TGID: %s",
system_name, bridge_key, entry["SYSTEM"], entry_ts, int_id(entry_tgid_b),
)
if self._report_factory and hasattr(self._report_factory, "send_bridge_event"):
try:
self._report_factory.send_bridge_event(
"GROUP VOICE,START,TX,{},{},{},{},{},{}".format(
entry["SYSTEM"], int_id(stream_id), int_id(peer_id), int_id(rf_src), entry_ts, int_id(entry_tgid_b)
)
)
except Exception:
pass
_ts_st["TX_TIME"] = pkt_time
_ts_st["TX_TYPE"] = dtype_vseq
# Slot bit rewrite (legacy bridge.py 457-460 / 770-773)
_src_entry_ts = slot
if _src_entry_ts != entry_ts:
_tmp_bits = _bits ^ (1 << 7)
else:
_tmp_bits = _bits
_tmp_data = b"".join([data[:8], entry_tgid_b, data[11:15], bytes([_tmp_bits]), data[16:20]])
# LC rewrite (exact port of legacy bridge.py 468-482 / 781-799)
dmrbits = bitarray(endian="big")
dmrbits.frombytes(dmrpkt)
if frame_type == HBPF_DATA_SYNC and dtype_vseq == HBPF_SLT_VHEAD:
dmrbits = _ts_st["TX_H_LC"][0:98] + dmrbits[98:166] + _ts_st["TX_H_LC"][98:197]
elif frame_type == HBPF_DATA_SYNC and dtype_vseq == HBPF_SLT_VTERM:
dmrbits = _ts_st["TX_T_LC"][0:98] + dmrbits[98:166] + _ts_st["TX_T_LC"][98:197]
if self._report_factory and hasattr(self._report_factory, "send_bridge_event"):
try:
call_duration = pkt_time - _ts_st.get("TX_START", pkt_time)
self._report_factory.send_bridge_event(
"GROUP VOICE,END,TX,{},{},{},{},{},{},{:.2f}".format(
entry["SYSTEM"], int_id(stream_id), int_id(peer_id), int_id(rf_src), entry_ts, int_id(entry_tgid_b), call_duration
)
)
except Exception:
pass
elif dtype_vseq in (1, 2, 3, 4):
_tmp_data = b"".join([_tmp_data, dmrpkt_out, data[53:55]])
try:
dmrbits = dmrbits[0:116] + _ts_st["TX_EMB_LC"][dtype_vseq] + dmrbits[148:264]
except Exception:
pass
dmrpkt_out = dmrbits.tobytes()
# Legacy OBP source: _tmp_data + dmrpkt + b'\x00\x00' (bridge.py 483)
# Legacy HBP source: _tmp_data + dmrpkt + _data[53:55] (bridge.py 800)
if source_is_obp:
_tmp_data = b"".join([_tmp_data, dmrpkt_out, b"\x00\x00"])
else:
_tmp_data = b"".join([_tmp_data, dmrpkt_out, data[53:55]])
try:
self._send_to_system(
entry["SYSTEM"], _tmp_data,
_hops=_hops, _ber=_ber, _rssi=_rssi,
_source_server=_source_server, _source_rptr=_source_rptr,
)
forwarded.append(entry["SYSTEM"])
except Exception as e:
logger.warning("(ROUTER) send_to_system %s failed: %s", entry.get("SYSTEM"), e)
self._send_to_system(
entry["SYSTEM"], _tmp_data,
_hops=_hops, _ber=_ber, _rssi=_rssi,
_source_server=_source_server, _source_rptr=_source_rptr,
)
forwarded.append(entry["SYSTEM"])
except Exception as e:
logger.warning("(ROUTER) send_to_system %s failed: %s", entry.get("SYSTEM"), e)
# Legacy bridge_master routerOBP dmrd_received ~2420-2434: after to_target, VTERM resets lastSeq;
# _fin only when REPORT (blocks further packets on this stream_id from this source).
if source_is_obp and frame_type == HBPF_DATA_SYNC and dtype_vseq == HBPF_SLT_VTERM:
_src_p = protocols.get(system_name) if protocols else None
_obp_st = getattr(_src_p, "_obp_streams", None) if _src_p else None
if _obp_st is not None and stream_id in _obp_st:
_obp_st[stream_id]["lastSeq"] = False
if self._report_factory and hasattr(self._report_factory, "send_bridge_event"):
_obp_st[stream_id]["_fin"] = True
if forwarded:
if frame_type == HBPF_DATA_SYNC and dtype_vseq == HBPF_SLT_VHEAD:
logger.info(
@ -1475,8 +1674,8 @@ class BridgeUseCases:
)
else:
logger.debug(
"(ROUTER) No ACTIVE targets for TG %s from %s (bridge has %s entries)",
bridge_key, system_name, len(bridges.get(bridge_key, [])),
"(ROUTER) No ACTIVE targets forwarded for TG %s from %s (%s bridge tables)",
bridge_key, system_name, len(bridges),
)
def _pvt_call_received(

@ -181,6 +181,9 @@ class HBPProtocol(DatagramProtocol):
self._config.get("TARGET_IP", ""),
self._config.get("TARGET_PORT", ""),
)
# bridge_master.routerOBP.to_target skips ENHANCED targets when '_bcka' not in SYSTEMS[name].
# Seed so cross-OBP forwarding works before the first inbound BCKA/DMR on *this* leg.
self._config["_bcka"] = time.time()
if self._config.get("ENHANCED_OBP"):
self._bcka_loop = task.LoopingCall(self._obp_send_bcka)
self._bcka_loop.start(10)
@ -228,7 +231,8 @@ class HBPProtocol(DatagramProtocol):
if self._config.get("MODE") == "MASTER":
self.send_peers(_packet, _hops, _ber, _rssi, _source_server, _source_rptr)
elif self._config.get("MODE") == "OPENBRIDGE":
if "STUN" in self._CONFIG:
# Global STUN (config) or per-system BCST (hblink sets _config['_STUN'] on BCST RX)
if "STUN" in self._CONFIG or self._config.get("_STUN"):
logger.info("(%s) Bridge STUNned, discarding", self._system)
return
if not _hops:
@ -236,7 +240,7 @@ class HBPProtocol(DatagramProtocol):
if _packet[:3] == DMR and self._config.get("TARGET_IP"):
_sid = self._CONFIG.get("GLOBAL", {}).get("SERVER_ID", b"\x00\x00\x00\x00")
_server_id = _sid if isinstance(_sid, bytes) and len(_sid) >= 4 else bytes_4(int(_sid) & 0xFFFFFFFF if isinstance(_sid, int) else 0)
_passphrase = self._config.get("PASSPHRASE", b"")
_passphrase = _get_passphrase_bytes(self._config)
_target_addr = (self._config["TARGET_IP"], self._config["TARGET_PORT"])
if "VER" in self._config and self._config["VER"] > 4:
_ver = VER.to_bytes(1, "big")
@ -948,8 +952,11 @@ class HBPProtocol(DatagramProtocol):
_rf_src: bytes = b"\x00\x00\x00",
_peer_id: bytes = b"\x00\x00\x00\x00",
) -> bool:
"""Legacy bridge_master OBP: stream state, 1ST, _fin, duplicate/seq handling. Returns True if packet should be forwarded to bridge."""
"""Port of bridge_master.py dmrd_received: OBP STATUS[_stream_id] packet control (group/vcsbk)."""
now = time.time()
_h = blake2b(digest_size=16)
_h.update(_data)
_pkt_crc = _h.digest()
# Trim old streams (legacy: 180s)
if _stream_id not in self._obp_streams:
to_remove = [sid for sid, st in self._obp_streams.items() if st.get("LAST", 0) < now - 180]
@ -964,44 +971,90 @@ class HBPProtocol(DatagramProtocol):
"lastSeq": False,
"lastData": False,
"packets": 0,
"loss": 0,
"crcs": set(),
"_fin": False,
"RFS": _rf_src,
"RX_PEER": _peer_id,
}
self._obp_streams[_stream_id]["crcs"].add(_pkt_crc)
return True
st = self._obp_streams[_stream_id]
if st.get("_fin"):
return False
st["LAST"] = now
st["packets"] = st.get("packets", 0) + 1
# Duplicate / out-of-order (legacy bridge_master 3256-3184)
if st.get("lastData") and st["lastData"] == _data and _seq > 1:
if "packets" in st:
st["packets"] = st["packets"] + 1
# Duplicate handling#
# Handle inbound duplicates
# Duplicate complete packet
if st["lastData"] and st["lastData"] == _data and _seq > 1:
st["loss"] += 1
logger.debug(
"(%s) *PacketControl* last packet is a complete duplicate of the previous one, disgarding. Stream ID:, %s TGID: %s, LOSS: %.2f%%",
self._system,
int_id(_stream_id),
int_id(_dst_id),
((st["loss"] / st["packets"]) * 100),
)
return False
# Duplicate SEQ number
if _seq and _seq == st["lastSeq"]:
st["loss"] += 1
logger.debug(
"(%s) *PacketControl* last packet is a complete duplicate, discarding. Stream ID: %s TGID: %s",
self._system, int_id(_stream_id), int_id(_dst_id),
"(%s) *PacketControl* Duplicate sequence number %s, disgarding. Stream ID:, %s TGID: %s, LOSS: %.2f%%",
self._system,
_seq,
int_id(_stream_id),
int_id(_dst_id),
((st["loss"] / st["packets"]) * 100),
)
return False
if _seq is not None and _seq == st.get("lastSeq"):
# Inbound out-of-order packets
if _seq and st["lastSeq"] and (_seq != 1) and (_seq < st["lastSeq"]):
st["loss"] += 1
logger.debug(
"(%s) *PacketControl* Duplicate sequence number %s, discarding. Stream ID: %s TGID: %s",
self._system, _seq, int_id(_stream_id), int_id(_dst_id),
"%s) *PacketControl* Out of order packet - last SEQ: %s, this SEQ: %s, disgarding. Stream ID:, %s TGID: %s, LOSS: %.2f%%",
self._system,
st["lastSeq"],
_seq,
int_id(_stream_id),
int_id(_dst_id),
((st["loss"] / st["packets"]) * 100),
)
return False
if _seq is not None and st.get("lastSeq") is not None and _seq != 1 and _seq < st["lastSeq"]:
# Duplicate DMR payload to previuos packet (by hash
if _seq > 0 and _pkt_crc in st["crcs"]:
st["loss"] += 1
logger.debug(
"(%s) *PacketControl* Out of order packet - last SEQ: %s, this SEQ: %s, discarding. Stream ID: %s TGID: %s",
self._system, st["lastSeq"], _seq, int_id(_stream_id), int_id(_dst_id),
"(%s) *PacketControl* DMR packet payload with hash: %s seen before in this stream, disgarding. Stream ID:, %s TGID: %s: SEQ:%s PACKETS: %s, LOSS: %.2f%% ",
self._system,
_pkt_crc,
int_id(_stream_id),
int_id(_dst_id),
_seq,
st["packets"],
((st["loss"] / st["packets"]) * 100),
)
return False
if _seq is not None and st.get("lastSeq") is not None and _seq > st["lastSeq"] + 1:
# Inbound missed packets
if _seq and st["lastSeq"] and _seq > (st["lastSeq"] + 1):
st["loss"] += 1
logger.debug(
"(%s) *PacketControl* Missed packet(s) - last SEQ: %s, this SEQ: %s. Stream ID: %s TGID: %s",
self._system, st["lastSeq"], _seq, int_id(_stream_id), int_id(_dst_id),
"(%s) *PacketControl* Missed packet(s) - last SEQ: %s, this SEQ: %s. Stream ID:, %s TGID: %s , LOSS: %.2f%%",
self._system,
st["lastSeq"],
_seq,
int_id(_stream_id),
int_id(_dst_id),
((st["loss"] / st["packets"]) * 100),
)
# Save this sequence number
st["lastSeq"] = _seq
# Save this packet
st["lastData"] = _data
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VTERM:
st["_fin"] = True
st["crcs"].add(_pkt_crc)
# Legacy bridge_master routerOBP: _fin is set after to_target + REPORT END (~2430-2432), not here.
return True
def _obp_datagram_received(self, _packet: bytes, _sockaddr: tuple[str, int]) -> None:
@ -1118,7 +1171,33 @@ class HBPProtocol(DatagramProtocol):
self.STATUS[_slot]["RX_RFS"] = _rf_src
self.STATUS[_slot]["RX_TIME"] = time.time()
if self._dmrd_received:
self._dmrd_received(self._system, _peer_id, _rf_src, _dst_id, _seq, _slot, _call_type, _frame_type, _dtype_vseq, _stream_id, _data)
# Legacy hblink DMRD v1: SERVER_ID + default rptr/hops/ber/rssi (`hblink.py` ~338–345, ~416)
_global = self._CONFIG.get("GLOBAL", {})
_sid = _global.get("SERVER_ID", b"\x00\x00\x00\x00")
_obp_ss = (
_sid
if isinstance(_sid, bytes) and len(_sid) >= 4
else bytes_4(int(_sid) & 0xFFFFFFFF if isinstance(_sid, int) else 0)
)
self._dmrd_received(
self._system,
_peer_id,
_rf_src,
_dst_id,
_seq,
_slot,
_call_type,
_frame_type,
_dtype_vseq,
_stream_id,
_data,
obp_use_parsed=True,
obp_hops=b"",
obp_source_server=_obp_ss,
obp_ber=b"\x00",
obp_rssi=b"\x00",
obp_source_rptr=b"\x00\x00\x00\x00",
)
self._config["_bcka"] = time.time()
else:
logger.warning("(%s) OpenBridge HMAC failed, packet discarded - OPCODE: %s SRC: %s", self._system, _packet[:4], _sockaddr)
@ -1127,6 +1206,9 @@ class HBPProtocol(DatagramProtocol):
if len(_packet) < 69:
return
_data = _packet[:53]
# Legacy hblink OPENBRIDGE DMRE: BER/RSSI before version split (`hblink.py` ~432–433)
_ber = _packet[53:54]
_rssi = _packet[54:55]
_embedded_version = _packet[55]
if _embedded_version > 4:
if len(_packet) < 89:
@ -1305,8 +1387,28 @@ class HBPProtocol(DatagramProtocol):
self.STATUS[_slot]["RX_RFS"] = _rf_src
self.STATUS[_slot]["RX_TIME"] = time.time()
_data_dmrd = DMRD + _data[4:]
_hops_out = _inthops.to_bytes(1, "big")
if self._dmrd_received:
self._dmrd_received(self._system, _peer_id, _rf_src, _dst_id, _seq, _slot, _call_type, _frame_type, _dtype_vseq, _stream_id, _data_dmrd)
# Legacy hblink DMRE: same fields passed to dmrd_received as after increment (`hblink.py` ~592–596)
self._dmrd_received(
self._system,
_peer_id,
_rf_src,
_dst_id,
_seq,
_slot,
_call_type,
_frame_type,
_dtype_vseq,
_stream_id,
_data_dmrd,
obp_use_parsed=True,
obp_hops=_hops_out,
obp_source_server=_source_server,
obp_ber=_ber,
obp_rssi=_rssi,
obp_source_rptr=_source_rptr,
)
self._config["_bcka"] = time.time()
elif _packet[:4] == EOBP:
logger.warning("(%s) *ProtoControl* KF7EEL EOBP protocol not supported", self._system)
@ -1324,6 +1426,35 @@ class HBPProtocol(DatagramProtocol):
self._config.pop("_no_target_log_time", None) # reset so next "no target" logs once
else:
logger.info("(%s) *BridgeControl* BCKA invalid KeepAlive, packet discarded", self._system)
# Source quench — legacy hblink.py OPENBRIDGE ~629-639 (sets CONFIG['_bcsq'][tgid]=stream_id)
if _packet[:4] == BCSQ and len(_packet) >= 31:
_hash_bcsq = _packet[11:]
_tgid_bcsq = _packet[4:7]
_stream_bcsq = _packet[7:11]
_ckhs_bcsq = hmac_new(self._config["PASSPHRASE"], _packet[:11], sha1).digest()
if compare_digest(_hash_bcsq, _ckhs_bcsq):
if "_bcsq" not in self._config:
self._config["_bcsq"] = {}
self._config["_bcsq"][_tgid_bcsq] = _stream_bcsq
else:
logger.warning(
"(%s) *BridgeControl* BCSQ invalid Source Quench, packet discarded - SRC: %s",
self._system,
_sockaddr,
)
# STUN — must match send_bcst: HMAC-SHA1 over opcode only (hblink.py ~282-285). RX used _packet[4:] in ~647 but that does not match TX.
if _packet[:4] == BCST and len(_packet) >= 24:
_hash_bcst = _packet[4:24]
_ckhs_bcst = hmac_new(self._config["PASSPHRASE"], _packet[:4], sha1).digest()
if compare_digest(_hash_bcst, _ckhs_bcst):
logger.trace("(%s) *BridgeControl* BCST STUN request received", self._system)
self._config["_STUN"] = True
else:
logger.warning(
"(%s) *BridgeControl* BCST invalid STUN, packet discarded - SRC: %s",
self._system,
_sockaddr,
)
if _packet[:4] == BCVE and len(_packet) >= 25:
_ver = int.from_bytes(_packet[4:5], "big")
_hash = _packet[5:25]

Loading…
Cancel
Save