Inbound confirmed PDUs of more than one block failed the packet CRC-32 on
every attempt. The receive path stepped 19 bytes per block on the wire and
stored 18 byte chunks, while storeConvertedRxPDU() reads 16 bytes of user
data per block, so every block after the first was misaligned.
A confirmed block on the wire is a sequence/flag byte, 16 bytes of user data
and a reserved byte (DFSI_PDU_CONFIRMED_BLOCK_LENGTH_BYTES). The single,
header and continuation frame cases now copy the user data through one
bounded helper, and reject a frame that is too short for its block count.
The single frame layout is checked against a frame captured from a Quantar,
using the subscriber's own packet CRC-32 and the IPv4 header checksum. No
capture of a header or continuation frame was available; those follow the
layout the transmit path generates.